DYNAMIC IMAGING OF CONTRAST ENHANCEMENT IN BRAIN-TUMORS

被引:26
作者
BULLOCK, PR
MANSFIELD, P
GOWLAND, P
WORTHINGTON, BS
FIRTH, JL
机构
[1] UNIV NOTTINGHAM,DEPT PHYS,NOTTINGHAM NG7 2RD,ENGLAND
[2] QUEENS MED CTR,NOTTINGHAM NG7 2UH,ENGLAND
[3] UNIV NOTTINGHAM,DEPT NEUROSURG,NOTTINGHAM NG7 2RD,ENGLAND
[4] UNIV NOTTINGHAM,DEPT ACAD RADIOL,NOTTINGHAM NG7 2RD,ENGLAND
关键词
D O I
10.1002/mrm.1910190217
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Gadolinium‐DTPA has been shown to be a good probe for demonstrating defects in the blood‐brain barrier, but it has a rapid rate of elimination so that peak circulating levels are short‐lived. In this study ultrafast echo‐planar imaging has been used in combination with a bolus injection of gadolinium‐DTPA to evaluate perfusion within brain tumors and to assess the degree of disruption of the blood‐brain barrier. The temporal profile of enhancement may allow discrimination between different tumor types. © 1991 Academic Press, Inc. Copyright © 1991 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:293 / 298
页数:6
相关论文
共 9 条
  • [1] FELIX R, 1988, DIAGNOSTIC IMAGING S, P13
  • [2] FINELLI DA, 1989, 75TH P RSNA M CHIC
  • [3] IMPROVEMENTS IN SNAP-SHOT NUCLEAR MAGNETIC-RESONANCE IMAGING
    HOWSEMAN, AM
    STEHLING, MK
    CHAPMAN, B
    COXON, R
    TURNER, R
    ORDIDGE, RJ
    CAWLEY, MG
    GLOVER, P
    MANSFIELD, P
    COUPLAND, RE
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (729) : 822 - 828
  • [4] QUANTITATION OF BLOOD-BRAIN-BARRIER DEFECT BY MAGNETIC-RESONANCE-IMAGING AND GADOLINIUM-DTPA IN PATIENTS WITH MULTIPLE-SCLEROSIS AND BRAIN-TUMORS
    LARSSON, HBW
    STUBGAARD, M
    FREDERIKSEN, JL
    JENSEN, M
    HENRIKSEN, O
    PAULSON, OB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (01) : 117 - 131
  • [5] MANSFIELD P, 1989, 6TH P RAD S GRAZ, P78
  • [6] SNAPSHOT HEAD IMAGING AT 0.5-T USING THE ECHO PLANAR TECHNIQUE
    ORDIDGE, RJ
    COXON, R
    HOWSEMAN, A
    CHAPMAN, B
    TURNER, R
    STEHLING, M
    MANSFIELD, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1988, 8 (01) : 110 - 115
  • [7] INVERSION-RECOVERY ECHO-PLANAR IMAGING (IR-EPI) AT 0.5-T
    STEHLING, MK
    ORDIDGE, RJ
    COXON, R
    MANSFIELD, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (03) : 514 - 517
  • [8] STEHLING MK, 1989, 8TH P ANN M SOC MAGN, V1, P358
  • [9] CHARACTERISTICS OF GADOLINIUM-DTPA COMPLEX - A POTENTIAL NMR CONTRAST AGENT
    WEINMANN, HJ
    BRASCH, RC
    PRESS, WR
    WESBEY, GE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 142 (03) : 619 - 624