Liver imaging with multidetector helical computed tomography

被引:4
作者
Nelson, RC
Spielmann, AL
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[2] Vancouver Hosp & Hlth Sci Ctr, Dept Radiol, Vancouver, BC V5Z 1M9, Canada
关键词
liver; liver computed tomography; liver neoplasms; computed tomography;
D O I
10.1097/00004728-200305001-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The speed and flexibility of multidetector computed tomography (MDCT) have led to improvements in liver imaging, particularly related to the detection and characterization of focal lesions. This report discusses the different phase of liver enhancement following the bolus administration of iodinated contrast material, and the enhancement pattern of various liver lesions during these phases. We also propose guidelines for designing protocols for MDCT of the liver and discuss the principles of contrast media delivery.
引用
收藏
页码:S9 / S16
页数:8
相关论文
共 26 条
[1]
Aortic and hepatic enhancement and tumor-to-liver contrast: Analysis of the effect of different concentrations of contrast material at multi-detector row helical CV [J].
Awai, K ;
Takada, K ;
Onishi, H ;
Hori, S .
RADIOLOGY, 2002, 224 (03) :757-763
[2]
Aortic and hepatic peak enhancement at CT: Effect of contrast medium injection rate - Pharmacokinetic analysis and experimental porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 206 (02) :455-464
[3]
CONTRAST MATERIAL FOR COMBINED ABDOMINAL AND PELVIC CT - CAN COST BE REDUCED BY INCREASING THE CONCENTRATION AND DECREASING THE VOLUME [J].
BAKER, ME ;
BEAM, C ;
LEDER, R ;
GULLIVER, D ;
PAINE, SS ;
DUNNICK, NR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) :637-641
[4]
Hepatocellular carcinoma: Evaluation with biphasic, contrast-enhanced, helical CT [J].
Baron, RL ;
Oliver, JH ;
Dodd, GD ;
Nalesnik, M ;
Holbert, BL ;
Carr, B .
RADIOLOGY, 1996, 199 (02) :505-511
[5]
HEPATIC SPIRAL CT - REDUCTION OF DOSE OF INTRAVENOUS CONTRAST MATERIAL [J].
BRINK, JA ;
HEIKEN, JP ;
FORMAN, HP ;
SAGEL, SS ;
MOLINA, PL ;
BROWN, PC .
RADIOLOGY, 1995, 197 (01) :83-88
[6]
Optimal section spacing in single-detector helical CT [J].
Brink, JA ;
Wang, G ;
McFarland, EG .
RADIOLOGY, 2000, 214 (02) :575-578
[7]
CHAMBERS TP, 1994, RADIOLOGY, V193, P512
[8]
INFLUENCE OF GLYCOGEN ON LIVER DENSITY - COMPUTED-TOMOGRAPHY FROM A METABOLIC PERSPECTIVE [J].
DWYER, A ;
DOPPMAN, JL ;
ADAMS, AJ ;
GIRTON, ME ;
CHERNICK, SS ;
CORNBLATH, M .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1983, 7 (01) :70-73
[9]
Multiphase hepatic CT with a multirow detector CT scanner [J].
Foley, WD ;
Mallisee, TA ;
Hohenwalter, MD ;
Wilson, CR ;
Quiroz, FA ;
Taylor, AJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (03) :679-685
[10]
DYNAMIC HEPATIC CT [J].
FOLEY, WD .