HEPATIC SPIRAL CT - REDUCTION OF DOSE OF INTRAVENOUS CONTRAST MATERIAL

被引:93
作者
BRINK, JA [1 ]
HEIKEN, JP [1 ]
FORMAN, HP [1 ]
SAGEL, SS [1 ]
MOLINA, PL [1 ]
BROWN, PC [1 ]
机构
[1] NYCOMED INC,NEW YORK,NY
关键词
COMPUTED TOMOGRAPHY (CT); CONTRAST MEDIA; HELICAL; IOHEXOL; LIVER; CT;
D O I
10.1148/radiology.197.1.7568859
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
PURPOSE: To assess the potential for reduction of contrast material dose in hepatic spiral computed tomography (CT). MATERIALS AND METHODS: Four hundred eighty-seven outpatients were randomized prospectively into nine biphasic and eight uniphasic injection protocols: 75, 100, or 125 mL of 240, 300, or 350 mg of iodine per milliliter of iohexol (18-44 grams of iodine). Protocols were compared according to the maximum hepatic enhancement (MAX) and the contrast enhancement index (CEI). RESULTS: Uniphasic injection was superior to biphasic injection for all protocols. No statistically significant difference in contrast enhancement was present for 38-44 grams of iodine with the uniphasic technique. Adequate enhancement thresholds (MAX > 50 HU, CEI at 30 HU > 300 HU X sec) were exceeded in more than 70% of heavy patients (> 183 lb [83 kg]) with uniphasic injection of 38 g. For thin patients (< 183 lb [83 kg]), uniphasic injection of 26 g produced adequate enhancement. CONCLUSION: Contrast material dose may be reduced by up to 40% in thin patients undergoing hepatic spiral CT after uniphasic injection of contrast material; this may result in substantial cost savings.
引用
收藏
页码:83 / 88
页数:6
相关论文
共 13 条
[1]
CONTRAST MATERIAL FOR COMBINED ABDOMINAL AND PELVIC CT - CAN COST BE REDUCED BY INCREASING THE CONCENTRATION AND DECREASING THE VOLUME [J].
BAKER, ME ;
BEAM, C ;
LEDER, R ;
GULLIVER, D ;
PAINE, SS ;
DUNNICK, NR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) :637-641
[3]
COMPARISON OF CONTRAST-MEDIA INJECTION RATES AND VOLUMES FOR HEPATIC DYNAMIC INCREMENTED COMPUTED-TOMOGRAPHY [J].
BERLAND, LL ;
LEE, JY .
INVESTIGATIVE RADIOLOGY, 1988, 23 (12) :918-922
[4]
DOSE REQUIREMENTS FOR A NONIONIC CONTRAST AGENT FOR SPIRAL COMPUTED-TOMOGRAPHY OF THE LIVER IN RABBITS [J].
BLUEMKE, DA ;
FISHMAN, EK ;
ANDERSON, JH .
INVESTIGATIVE RADIOLOGY, 1994, 29 (02) :195-200
[5]
COST-EFFECTIVE USE OF LOW-OSMOLALITY CONTRAST-MEDIA FOR CT OF THE LIVER - EVALUATION OF LIVER ENHANCEMENT PROVIDED BY VARIOUS DOSES OF IOHEXOL [J].
BREE, RL ;
PARISKY, YR ;
BERNARDINO, ME ;
COSTELLO, P ;
LEDER, R ;
BROWN, PC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (03) :579-583
[6]
HEPATIC HELICAL CT - CONTRAST MATERIAL INJECTION PROTOCOL [J].
FOLEY, WD ;
HOFFMANN, RG ;
QUIROZ, FA ;
KAHN, CE ;
PERRET, RS .
RADIOLOGY, 1994, 192 (02) :367-371
[7]
DYNAMIC HEPATIC CT [J].
FOLEY, WD .
RADIOLOGY, 1989, 170 (03) :617-622
[8]
DYNAMIC CONTRAST-ENHANCED CT OF THE LIVER - COMPARISON OF CONTRAST-MEDIUM INJECTION RATES AND UNIPHASIC AND BIPHASIC INJECTION PROTOCOLS [J].
HEIKEN, JP ;
BRINK, JA ;
MCCLENNAN, BL ;
SAGEL, SS ;
FORMAN, HP ;
DICROCE, J .
RADIOLOGY, 1993, 187 (02) :327-331
[9]
DYNAMIC INCREMENTAL CT - EFFECT OF VOLUME AND CONCENTRATION OF CONTRAST MATERIAL AND PATIENT WEIGHT ON HEPATIC ENHANCEMENT [J].
HEIKEN, JP ;
BRINK, JA ;
MCCLENNAN, BL ;
SAGEL, SS ;
CROWE, TM ;
GAINES, MV .
RADIOLOGY, 1995, 195 (02) :353-357
[10]
SPIRAL(HELICAL) CT [J].
HEIKEN, JP ;
BRINK, JA ;
VANNIER, MW .
RADIOLOGY, 1993, 189 (03) :647-656