Chemometric data analysis of pollutants in wastewater - a case study

被引:84
作者
Singh, KP
Malik, A
Mohan, D
Sinha, S
Singh, VK
机构
[1] Ind Toxicol Res Ctr, Environm Chem Sect, Lucknow 226001, Uttar Pradesh, India
[2] Natl Bot Res Inst, Lucknow 226001, Uttar Pradesh, India
关键词
wastewater; sewage treatment; multivariate analysis; cluster analysis; principal component; discriminant analysis; partial least squares;
D O I
10.1016/j.aca.2004.10.043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, chemometric techniques such as cluster analysis (CA), discriminant analysis (DA), principal component analysis (PCA) and partial least squares (PLS) were used to analyse the wastewater dataset to identify the factors which affect the composition of sewage of domestic origin, spatial and temporal variations, similarity/dissimilarity among the wastewater characteristics of cis- and trans-drains and discriminating variables. Samples collected from 24 wastewater drains in Lucknow city and from three sites on Gomti river in the month of January/February, May, August and November during the period of 5 years (1994-1999) were characterized for 32 parameters. The multivariate techniques successfully described the similarities/dissimilarities among the sewage drains on the basis of their wastewater characteristics and sources signifying the effect of routine domestic/commercial activities in respective drainage areas. Spatial and seasonal variations in wastewater composition were also determined successfully. CA generated six groups of drains on the basis of similar wastewater characteristic. PCA provided information on seasonal influence and compositional differences in sewage generated by domestic and industrial waste dominated drains and showed that drains influenced by mixed industrial effluents have high organic pollution load. DA rendered six variables (TDS, alkalinity, F, TKN, Cd and Cr) discriminating between cis- and trans-drains. PLS-DA showed dominance of Cd, Cr, NO3, PO4 and F in cis-drains wastewater. The results suggest that biological-process based STPs could treat wastewater both from the cis- as well as trans-drains, however, prior removal of toxic metals will be required from the cis-drains sewage. Further, seasonal variations in wastewater composition and pollution load could be the guiding factor for determining the STPs design parameters. The information generated would be useful in selection of process type and in designing of the proposed sewage treatment plants (STPs) for safe disposal of wastewater. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:15 / 25
页数:11
相关论文
共 19 条
[11]  
2-Z
[12]  
Otto M., 1998, Analytical Chemistry
[13]  
Palmborg C, 1998, AMBIO, V27, P53
[14]   Assessment of the surface water quality in Northern Greece [J].
Simeonov, V ;
Stratis, JA ;
Samara, C ;
Zachariadis, G ;
Voutsa, D ;
Anthemidis, A ;
Sofoniou, M ;
Kouimtzis, T .
WATER RESEARCH, 2003, 37 (17) :4119-4124
[15]   Multivariate statistical techniques for the evaluation of spatial and temporal variations in water quality of Gomti River (India) - a case study [J].
Singh, KP ;
Malik, A ;
Mohan, D ;
Sinha, S .
WATER RESEARCH, 2004, 38 (18) :3980-3992
[16]   Assessment of seasonal and polluting effects on the quality of river water by exploratory data analysis [J].
Vega, M ;
Pardo, R ;
Barrado, E ;
Debán, L .
WATER RESEARCH, 1998, 32 (12) :3581-3592
[17]   The contribution of domestic sources to levels of key organic and inorganic pollutants in sewage: The case of Melbourne, Australia [J].
Wilkie, PJ ;
Hatzimihalis, G ;
Koutoufides, P ;
Connor, MA .
WATER SCIENCE AND TECHNOLOGY, 1996, 34 (3-4) :63-70
[18]   PRINCIPAL COMPONENT ANALYSIS [J].
WOLD, S ;
ESBENSEN, K ;
GELADI, P .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1987, 2 (1-3) :37-52
[19]   Pattern recognition techniques for the evaluation of spatial and temporal variations in water quality. A case study: Suquia River basin (Cordoba-Argentina) [J].
Alberto, WD ;
Del Pilar, DM ;
Valeria, AM ;
Fabiana, PS ;
Cecilia, HA ;
De Los Angeles, BM .
WATER RESEARCH, 2001, 35 (12) :2881-2894