Microanalysis by monochromatic microprobe x-ray fluorescence - physical basis, properties, and future prospects

被引:21
作者
Chen, ZW [1 ]
Wittry, DB
机构
[1] Univ So Calif, Dept Mat Sci & Engn, Los Angeles, CA 90089 USA
[2] Univ So Calif, Dept Mat Sci & Engn, Los Angeles, CA 90089 USA
[3] Univ So Calif, Dept Elect Engn, Los Angeles, CA 90089 USA
关键词
D O I
10.1063/1.368105
中图分类号
O59 [应用物理学];
学科分类号
摘要
A monochromatic microprobe for x-ray fluorescence is obtained by a doubly-curved crystal diffractor which focuses characteristic radiation from a small laboratory-based x-ray source. Monochromatic microprobe x-ray fluorescence (MMXRF) provides unique advantages over conventional XRF, i.e., smaller analytical volume, higher sensitivity for the detection of impurities, and more accurate quantitation. Possible photon energies, voltage for the x-ray source, and type of diffractor geometry are discussed. Calculations of geometric aberration, collection solid angle, and beam intensity are given for a Johann-based diffractor. Properties of a mica diffractor used to focus Cu K alpha(1) x rays are predicted by ray tracing and experimentally verified by x-ray topographs and images of the focal spot. With the mica diffractor and a 20 mu m x-ray source at 30 kV and 0.1 mA, similar to 1.1 x 10(8) photons/s were obtained in a probe of 57 mu m x 43 mu m and probes less than 10 mu m appear to be theoretically possible. Energy dispersive spectra for bulk specimens of Si, GaAs,Mg, and Muscovite obtained with the Cu K alpha(1) probe exhibited extremely high signal/background ratios. The sources of background and reasons for low values are discussed. The low background resulted in predicted detection limits as low as 1.6 ppm for a measurement time of 500 s. Detection limits in the ppb range should be possible with higher power for the x-ray source, better detectors for energy dispersive spectrometry, improved diffractor fabrication and appropriate selection of the exciting photon energy. (C) 1998 American Institute of Physics. [S0021-8979(98)07014-5].
引用
收藏
页码:1064 / 1073
页数:10
相关论文
共 23 条
[11]  
Jenkins R., 1981, QUANTITATIVE XRAY SP
[12]   The production-aperture x-ray spectra with the help of concave crystals [J].
Johann, H. H. .
ZEITSCHRIFT FUR PHYSIK, 1931, 69 (3-4) :185-206
[13]   A novel, accurate-focusing X-ray spectrometer. [J].
Johansson, Tryggve .
ZEITSCHRIFT FUR PHYSIK, 1933, 82 (7-8) :507-528
[14]  
MARKOWICZ AA, 1993, HDB XRAY SPECTROMETR, P35
[15]  
MEISEL VA, 1965, Z KRISTALLOGR, V122, P148
[16]  
NIELSON KK, 1979, ADV XRAY ANAL, V22, P303
[17]   CHARACTERISTIC FLUORESCENCE CORRECTIONS IN ELECTRON-PROBE MICROANALYSIS [J].
REED, SJB .
BRITISH JOURNAL OF APPLIED PHYSICS, 1965, 16 (07) :913-&
[18]   PROPERTIES OF CURVED X-RAY DIFFRACTORS WITH STEPPED SURFACES [J].
WITTRY, DB ;
SUN, SQ .
JOURNAL OF APPLIED PHYSICS, 1991, 69 (07) :3886-3892
[19]   X-RAY OPTICS OF DOUBLY CURVED DIFFRACTORS .2. [J].
WITTRY, DB ;
SUN, SQ .
JOURNAL OF APPLIED PHYSICS, 1992, 71 (02) :564-568
[20]   LARGE APERTURE POINT-FOCUSING DIFFRACTOR FOR X-RAYS [J].
WITTRY, DB ;
GOLIJANIN, DM .
APPLIED PHYSICS LETTERS, 1988, 52 (17) :1381-1382