Electron beam CT versus 16-MDCT on the variability of repeated coronary artery calcium measurements in a variable heart rate phantom

被引:36
作者
Horiguchi, J
Shen, Y
Akiyama, Y
Hirai, N
Sasaki, K
Ishifuro, M
Nakanishi, T
Ito, K
机构
[1] Hiroshima Univ Hosp, Dept Clin Radiol, Minami Ku, Hiroshima 7348551, Japan
[2] GE Co, Yokogawa Med Syst, Imaging Applicat Tech Ctr, Tokyo, Japan
[3] Mazda Motor Corp, Mazda Hosp, Dept Radiol, Hiroshima, Japan
[4] Hiroshima Univ, Grad Sch Biomed Sci, Programs Appl Biomed,Dept Radiol, Div Med Intelligence & Informat, Hiroshima, Japan
关键词
D O I
10.2214/AJR.04.1057
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. High reproducibility of coronary artery calcium (CAC) scoring is a key requirement for monitoring the progression of coronary atherosclerosis. The purposes of this study were to compare electron beam CT and 16-MDCT scanners in the variability of repeated CAC measurements and to assess the factors influencing this variability. MATERIALS AND METHODS. CAC models of different sizes attached to a cardiac phantom with a programmable variable heart rate were scanned three times, and interscan variability of the CAC measurement was calculated each time. For helical CT, different slice-thickness images of either retrospective ECG-gated or prospective ECG-triggering reconstruction were obtained. The detection of small amounts of calcium, variability of the Agatston score, and CAC measurement algorithms (Agatston, volume, and mass scores) were compared between CT scanners and protocols. RESULTS. All 1-mm-sized calcium models were detected on 0.625- and 1.25-mm helical CT, whereas some were missed on electron beam CT and 2.5-mm helical CT. Retrospective ECG-gated thin-slice helical CT showed the lowest variability. Reduction of variability by volume and mass scoring algorithms was less effective on 0.625- and 1.25-mm-thickness CT. CONCLUSION. Retrospective ECG-gated thin-slice helical CT has the potential to be a useful toot for monitoring coronary atherosclerosis.
引用
收藏
页码:995 / 1000
页数:6
相关论文
共 27 条
[1]   Overlapping cross-sections significantly improve the reproducibility of coronary calcium measurements by electron beam tomography: A phantom study [J].
Achenbach, S ;
Meissner, F ;
Ropers, D ;
Pohle, K ;
Kusus, M ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (04) :569-573
[2]   Variability of repeated coronary artery calcium measurements by electron beam tomography [J].
Achenbach, S ;
Ropers, D ;
Möhlenkamp, S ;
Schmermund, A ;
Muschiol, G ;
Groth, J ;
Kusus, M ;
Regenfus, M ;
Daniel, WG ;
Erbel, R ;
Moshage, W .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (02) :210-+
[3]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[4]   Prediction of coronary events with electron beam computed tomography [J].
Arad, Y ;
Spadaro, LA ;
Goodman, K ;
Newstein, D ;
Guerci, AD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (04) :1253-1260
[5]   SMALL LESIONS IN THE HEART IDENTIFIED AT ELECTRON-BEAM CT - CALCIFICATION OR NOISE [J].
BIELAK, LF ;
KAUFMANN, RB ;
MOLL, PP ;
MCCOLLOUGH, CH ;
SCHWARTZ, RS ;
SHEEDY, PF .
RADIOLOGY, 1994, 192 (03) :631-636
[6]   Rates of progression of coronary calcium by electron beam tomography [J].
Budoff, MJ ;
Lane, KL ;
Bakhsheshi, H ;
Mao, S ;
Grassmann, BO ;
Friedman, BC ;
Brundage, BH .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (01) :8-11
[7]   Sensitivity of two electron beam tomography protocols for the detection and quantification of coronary artery calcium [J].
Callister, T ;
Janowitz, W ;
Raggi, P .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (06) :1743-1746
[8]   Effect of HMG-Coa reductase inhibitors on coronary artery disease as assessed by electron-beam computed tomography [J].
Callister, TQ ;
Raggi, P ;
Cooil, B ;
Lippolis, NJ ;
Russo, DJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) :1972-1978
[9]   Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method [J].
Callister, TQ ;
Cooil, B ;
Raya, SP ;
Lippolis, NJ ;
Russo, DJ ;
Raggi, P .
RADIOLOGY, 1998, 208 (03) :807-814
[10]   ACCURACY OF QUANTIFYING CORONARY HYDROXYAPATITE WITH ELECTRON-BEAM TOMOGRAPHY [J].
DETRANO, R ;
KANG, XP ;
MAHAISAVARIYA, P ;
TANG, WY ;
COLOMBO, A ;
MOLLOI, S ;
GARNER, D ;
NICKERSON, S .
INVESTIGATIVE RADIOLOGY, 1994, 29 (08) :733-738