Variability of repeated coronary artery calcium measurements by electron beam tomography

被引:113
作者
Achenbach, S
Ropers, D
Möhlenkamp, S
Schmermund, A
Muschiol, G
Groth, J
Kusus, M
Regenfus, M
Daniel, WG
Erbel, R
Moshage, W
机构
[1] Univ Erlangen Nurnberg, Dept Internal Med Cardiol 2, Erlangen, Germany
[2] Univ Essen Gesamthsch, Dept Cardiol, Essen, Germany
关键词
D O I
10.1016/S0002-9149(00)01319-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In 120 patients, the mean interscan variability of coronary calcium quantification by electron beam tomography was 19.9% (median 7.8%) for the traditional calcium score, and 16.2% (median 5.7%) for Volumetric scoring. Although this difference was not significant, there: was a significant influence of the total amount of calcium, number of acquired images, and image noise on interscan reproducibility.
引用
收藏
页码:210 / +
页数:5
相关论文
共 14 条
[1]   In-plane coronary arterial motion velocity: Measurement with electron-beam CT [J].
Achenbach, S ;
Ropers, D ;
Holle, J ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
RADIOLOGY, 2000, 216 (02) :457-463
[2]   Comparison of two different software systems for electron-beam CT-derived quantification of coronary calcification [J].
Adamzik, M ;
Schmermund, A ;
Reed, JE ;
Adamzik, S ;
Behrenbeck, T ;
Sheedy, PF .
INVESTIGATIVE RADIOLOGY, 1999, 34 (12) :767-773
[3]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[4]   SMALL LESIONS IN THE HEART IDENTIFIED AT ELECTRON-BEAM CT - CALCIFICATION OR NOISE [J].
BIELAK, LF ;
KAUFMANN, RB ;
MOLL, PP ;
MCCOLLOUGH, CH ;
SCHWARTZ, RS ;
SHEEDY, PF .
RADIOLOGY, 1994, 192 (03) :631-636
[5]   Rates of progression of coronary calcium by electron beam tomography [J].
Budoff, MJ ;
Lane, KL ;
Bakhsheshi, H ;
Mao, S ;
Grassmann, BO ;
Friedman, BC ;
Brundage, BH .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (01) :8-11
[6]   Effect of HMG-Coa reductase inhibitors on coronary artery disease as assessed by electron-beam computed tomography [J].
Callister, TQ ;
Raggi, P ;
Cooil, B ;
Lippolis, NJ ;
Russo, DJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) :1972-1978
[7]   Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method [J].
Callister, TQ ;
Cooil, B ;
Raya, SP ;
Lippolis, NJ ;
Russo, DJ ;
Raggi, P .
RADIOLOGY, 1998, 208 (03) :807-814
[8]   REPRODUCIBILITY OF THE MEASUREMENT OF CORONARY CALCIUM WITH ULTRAFAST COMPUTED-TOMOGRAPHY [J].
DEVRIES, S ;
WOLFKIEL, C ;
SHAH, V ;
CHOMKA, E ;
RICH, S .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (14) :973-975
[9]   COMPARISON OF SERIAL QUANTITATIVE-EVALUATION OF CALCIFIED CORONARY-ARTERY PLAQUE BY ULTRAFAST COMPUTED-TOMOGRAPHY IN PERSONS WITH AND WITHOUT OBSTRUCTIVE CORONARY-ARTERY DISEASE [J].
JANOWITZ, WR ;
AGATSTON, AS ;
VIAMONTE, M .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (01) :1-6
[10]   Progression of coronary artery calcification: A pilot study [J].
Maher, JE ;
Bielak, LF ;
Raz, JA ;
Sheedy, PF ;
Schwartz, RS ;
Peyser, PA .
MAYO CLINIC PROCEEDINGS, 1999, 74 (04) :347-355