Starter sequence for steady-state free precession imaging

被引:9
作者
Foxall, DL [1 ]
机构
[1] Philips Med Syst Cleveland Inc, Cleveland, OH 44143 USA
关键词
steady-state free precession; starter sequence; transient signal oscillations; banding artifacts; longitudinal preparation;
D O I
10.1002/mrm.20437
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The dynamic equilibrium exploited by balanced steady-state free precession imaging develops slowly because its formation is dependent on both spin-spin and spin-lattice relaxation times. Attempting to image before steady state is established results in artifacts due to transient signal oscillations. Using a starter sequence to precondition the spin system can significantly reduce the delay before imaging. An improved design for a steady-state starter sequence is presented. The new sequence has the advantage of uniformly exciting the steady-state response for all resonance offsets and can be phase cycled to suppress banding artifacts. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:919 / 929
页数:11
相关论文
共 17 条
[1]   Steady-state preparation for spoiled gradient echo imaging [J].
Busse, RF ;
Riederer, SJ .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :653-661
[2]  
Coenegrachts KL, 2004, RADIOLOGY, V231, P237, DOI [10.1148/radiol.2311030044, 10.1148/radioi.2311030044]
[3]  
Deimling M., 1994, PROC 2 ANN M SMR SAN, P495
[4]   Reduction of transient signal oscillations in True-FISP using a linear flip angle series magnetization preparation [J].
Deshpande, VS ;
Chung, YC ;
Zhang, Q ;
Shea, SM ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) :151-157
[5]   Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at .2 T [J].
Duerk, JL ;
Lewin, JS ;
Wendt, M ;
Petersilge, C .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :203-208
[6]   Frequency-modulated steady-state free precession imaging [J].
Foxall, DL .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (03) :502-508
[7]  
FOXALL DL, Patent No. 0095138
[8]  
FREEMAN R, 1988, HDB NUCL MAGNETIC RE, P237
[9]   Characterization and reduction of the transient response in steady-state MR imaging [J].
Hargreaves, BA ;
Vasanawala, SS ;
Pauly, JM ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) :149-158
[10]   Optimization of signal behavior in the transition to driven equilibrium in steady-state free precession sequences [J].
Hennig, J ;
Speck, O ;
Scheffler, K .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (05) :801-809