Hip Screw Migration Testing: First Results for Hip Screws and Helical Blades Utilizing a New Oscillating Test Method

被引:57
作者
Born, Christopher T. [1 ]
Karich, Bernhard [2 ]
Bauer, Christoph [3 ]
von Oldenburg, Geert [3 ]
Augat, Peter [4 ]
机构
[1] Brown Univ, Dept Orthopaed Surg, Providence, RI 02905 USA
[2] Heinrich Braun Krankenhaus, Zwickau, Germany
[3] Stryker Osteosynth, Schonkirchen, Germany
[4] BG Unfallklin Murnau, Murnau, Germany
关键词
intertrochanteric fracture; cut-out; helical blade; hip screw; gamma nail; GAMMA LOCKING NAIL; FRACTURE FIXATION; INTERTROCHANTERIC FRACTURES; INTRAMEDULLARY NAIL; FAILURE; IMPLANT; METAANALYSIS; RESISTANCE; WALKING; CADAVER;
D O I
10.1002/jor.21236
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Despite continued improvement in the methods and devices used to treat intertrochanteric fractures, there remains an unacceptable amount of failures. The cut-out rate for hip screws has been recorded up to 8.3%. To evaluate the migration of different implants under physiological loads, a multiplanar biomechanical test method for hip screws was developed, the first to incorporate a simulation of the human gait cycle by an oscillating flexion/extension movement of the test device. The new method was used to compare different hip screw and blade designs with respect to their directional migration resistance. The test method generated failure modes that were consistent with those observed clinically. Under cyclic loading, the hip screws migrated predominantly in a cephalad direction. In contrast, the helical blades exhibited a distinct migration in their axial direction. The Gamma3 hip screw design showed a significantly higher migration resistance compared with other screw and helical blade designs. The results demonstrate the ability of hip screws to significantly reduce axial migration and prevent cut-out under simulated walking loads. Further, the new multiplanar test method creates a physiological environment that can be used to optimize designs for intertrochanteric fracture fixation. (C) 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 29:760-766, 2011
引用
收藏
页码:760 / 766
页数:7
相关论文
共 28 条
[1]
AHLO A, 1999, ACTA ORTHOP SCAND, V70, P141
[2]
Salvage of Failed Hip Fracture Fixation [J].
Angelini, Mark ;
McKee, Michael D. ;
Waddell, James P. ;
Haidukewych, George ;
Schemitsch, Emil H. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (06) :471-478
[3]
Implant-related complications in the treatment of unstable intertrochanteric fractures:: meta-analysis of dynamic screw-plate versus dynamic screw-intramedullary nail devices [J].
Audigé, L ;
Hanson, B ;
Swiontkowski, MF .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 (04) :197-203
[4]
THE VALUE OF THE TIP-APEX DISTANCE IN PREDICTING FAILURE OF FIXATION OF PERITROCHANTERIC FRACTURES OF THE HIP [J].
BAUMGAERTNER, MR ;
CURTIN, SL ;
LINDSKOG, DM ;
KEGGI, JM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (07) :1058-1064
[5]
HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[6]
BOJAN A, 2004, J ORTHOP TRAUMA S, V18, P21
[7]
Immediate weight-bearing after treatment of a comminuted fracture of the femoral shaft with a statically locked intramedullary nail [J].
Brumback, RJ ;
Toal, TR ;
Murphy-Zane, MS ;
Novak, VP ;
Belkoff, SM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (11) :1538-1544
[8]
Lag screws for hip fracture fixation: Evaluation of migration resistance under simulated walking [J].
Ehmke, LW ;
Fitzpatrick, DC ;
Krieg, JC ;
Madey, SM ;
Bottlang, M .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (06) :1329-1335
[9]
FITZPATRICK DC, 2009, P ORTH TRAUM ASS ANN, P157