Non-spectral interference effects in inductively coupled plasma mass spectrometry using direct injection high efficiency and microconcentric nebulisation

被引:41
作者
Björn, E [1 ]
Frech, W [1 ]
机构
[1] Umea Univ, Dept Chem, S-90187 Umea, Sweden
关键词
D O I
10.1039/b007514k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Non-spectral interference effects in inductively coupled plasma mass spectrometry (ICP-MS) were investigated for the direct injection high efficiency nebuliser (DIHEN) the large bore DIHEN (LB-DIHEN) and a microconcentric nebuliser (MCN) with a cyclone spray chamber. Interference effects from nitric and sulfuric acid, methanol and sodium nitrate solutions were studied. Eight elements with different ionisation potentials (IP) and atomic masses were monitored at various nebuliser gas flow rates. The processes giving rise to interference effects observed with the DIHEN were investigated by monitoring relative analyte sensitivities at different radial plasma positions. It was found that the average magnitude of interference effects decreased in the order MCN approximate to DIHEN > LB-DIHEN, showing that analytical performance is improved by removing the spray chamber. It is suggested that remaining interference effects observed for the DIHEN are caused by a matrix induced spatial redistribution of the aerosol in the plasma due to differences in droplet. size distribution and density between water and the matrix solutions. In addition, the high plasma solvent load with the DIHEN results in a pronounced negative correlation between relative analyte signal magnitude and IP. For the LB-DIHEN, these effects were smaller, and other element specific interference effects dominated. For the eight elements monitored, element specific interference effects increased in the order MCN < DIHEN < LB-DIHEN. Transient acid effects were also investigated and found to be virtually eliminated by the use of a DIHEN instead of the MCN system. For the latter, stabilisation times of 3-10 mill were necessary when changing the nitric acid concentration between 0.22 and 2.2 mol 1(-1).
引用
收藏
页码:4 / 11
页数:8
相关论文
共 37 条
[1]   A large bore-direct injection high efficiency nebulizer for inductively coupled plasma spectrometry [J].
Acon, BW ;
McLean, JA ;
Montaser, A .
ANALYTICAL CHEMISTRY, 2000, 72 (08) :1885-1893
[2]   USE OF ORGANIC-SOLVENTS FOR INDUCTIVELY COUPLED PLASMA ANALYSES [J].
BARRETT, P ;
PRUSZKOWSKA, E .
ANALYTICAL CHEMISTRY, 1984, 56 (11) :1927-1930
[3]   STUDY OF THE EFFECTS OF CONCOMITANT ELEMENTS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BEAUCHEMIN, D ;
MCLAREN, JW ;
BERMAN, SS .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (03) :467-490
[4]  
BJORN E, 1999, 1999 FACSS C VANC BC
[5]   INTERFERENCE FROM EASILY IONIZABLE ELEMENT MATRICES IN INDUCTIVELY COUPLED PLASMA EMISSION-SPECTROMETRY - A SPATIAL STUDY [J].
BLADES, MW ;
HORLICK, G .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1981, 36 (09) :881-900
[6]  
BOORN AW, 1987, INDUCTIVELY COUPLED, P244
[7]   AEROSOL TRANSPORT MODEL FOR ATOMIC SPECTROMETRY [J].
BROWNER, RF ;
BOORN, AW ;
SMITH, DD .
ANALYTICAL CHEMISTRY, 1982, 54 (08) :1411-1419
[8]   EXPERIMENTAL EVALUATION OF THE NUKIYAMA-TANASAWA EQUATION FOR PNEUMATIC NEBULIZERS USED IN PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
CANALS, A ;
HERNANDIS, V ;
BROWNER, RF .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (01) :61-66
[9]   FUNDAMENTAL-STUDIES ON PNEUMATIC GENERATION AND AEROSOL TRANSPORT IN ATOMIC SPECTROMETRY - EFFECT OF MINERAL ACIDS ON EMISSION INTENSITY IN INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
CANALS, A ;
HERNANDIS, V ;
TODOLI, JL ;
BROWNER, RF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (4-7) :305-321
[10]   Comparison of the effect of acetic acid with axially and radially viewed inductively coupled plasma atomic emission spectrometry: influence of the operating conditions [J].
Dubuisson, C ;
Poussel, E ;
Mermet, JM ;
Todoli, JL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (01) :63-67