Non-spectral interference effects in inductively coupled plasma mass spectrometry using direct injection high efficiency and microconcentric nebulisation

被引:41
作者
Björn, E [1 ]
Frech, W [1 ]
机构
[1] Umea Univ, Dept Chem, S-90187 Umea, Sweden
关键词
D O I
10.1039/b007514k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Non-spectral interference effects in inductively coupled plasma mass spectrometry (ICP-MS) were investigated for the direct injection high efficiency nebuliser (DIHEN) the large bore DIHEN (LB-DIHEN) and a microconcentric nebuliser (MCN) with a cyclone spray chamber. Interference effects from nitric and sulfuric acid, methanol and sodium nitrate solutions were studied. Eight elements with different ionisation potentials (IP) and atomic masses were monitored at various nebuliser gas flow rates. The processes giving rise to interference effects observed with the DIHEN were investigated by monitoring relative analyte sensitivities at different radial plasma positions. It was found that the average magnitude of interference effects decreased in the order MCN approximate to DIHEN > LB-DIHEN, showing that analytical performance is improved by removing the spray chamber. It is suggested that remaining interference effects observed for the DIHEN are caused by a matrix induced spatial redistribution of the aerosol in the plasma due to differences in droplet. size distribution and density between water and the matrix solutions. In addition, the high plasma solvent load with the DIHEN results in a pronounced negative correlation between relative analyte signal magnitude and IP. For the LB-DIHEN, these effects were smaller, and other element specific interference effects dominated. For the eight elements monitored, element specific interference effects increased in the order MCN < DIHEN < LB-DIHEN. Transient acid effects were also investigated and found to be virtually eliminated by the use of a DIHEN instead of the MCN system. For the latter, stabilisation times of 3-10 mill were necessary when changing the nitric acid concentration between 0.22 and 2.2 mol 1(-1).
引用
收藏
页码:4 / 11
页数:8
相关论文
共 37 条
[11]   INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY - A REVIEW [J].
EVANS, EH ;
GIGLIO, JJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (01) :1-18
[12]   INFLUENCE OF OPERATING-CONDITIONS ON THE EFFECTS OF ACIDS IN INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
FERNANDEZ, A ;
MURILLO, M ;
CARRION, N ;
MERMET, JM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (03) :217-221
[13]   NONSPECTROSCOPIC INTERELEMENT INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
GILLSON, GR ;
DOUGLAS, DJ ;
FULFORD, JE ;
HALLIGAN, KW ;
TANNER, SD .
ANALYTICAL CHEMISTRY, 1988, 60 (14) :1472-1474
[14]   A COLLISIONAL RADIATIVE MODEL INCLUDING RADIATION TRAPPING AND TRANSPORT PHENOMENA FOR DIAGNOSTICS OF AN INDUCTIVELY COUPLED ARGON PLASMA [J].
HASEGAWA, T ;
HARAGUCHI, H .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1985, 40 (10-12) :1505-1515
[15]   INDUCTIVELY COUPLED PLASMA-OPTICAL EMISSION-SPECTROSCOPY - EXCITATION TEMPERATURES EXPERIENCED BY ANALYTE SPECIES [J].
KALNICKY, DJ ;
KNISELEY, RN ;
FASSEL, VA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1975, 30 (12) :511-525
[16]   DIRECT LIQUID SAMPLE INTRODUCTION FOR FLOW-INJECTION ANALYSIS AND LIQUID-CHROMATOGRAPHY WITH INDUCTIVELY COUPLED ARGON PLASMA SPECTROMETRIC DETECTION [J].
LAWRENCE, KE ;
RICE, GW ;
FASSEL, VA .
ANALYTICAL CHEMISTRY, 1984, 56 (02) :289-292
[17]   PRESERVATION OF ACCURACY AND PRECISION IN THE ANALYTICAL PRACTICE OF LOW-POWER ICP-AES [J].
MAESSEN, FJMJ ;
BALKE, J ;
DEBOER, JLM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1982, 37 (06) :517-526
[18]   ANALYTICAL ASPECTS OF ORGANIC-SOLVENT LOAD REDUCTION IN NORMAL-POWER ICPS BY AEROSOL THERMOSTATTING AT LOW-TEMPERATURES [J].
MAESSEN, FJMJ ;
SEEVERENS, PJH ;
KREUNING, G .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1984, 39 (9-11) :1171-1180
[19]   Evaluation of several commercially available spray chambers for use in inductively coupled plasma atomic emission spectrometry [J].
Maestre, S ;
Mora, J ;
Todolí, JL ;
Canals, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (01) :61-67
[20]   SOME EFFECTS OF LOW ACID CONCENTRATIONS IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
MARICHY, M ;
MERMET, M ;
MERMET, JM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1990, 45 (11) :1195-1201