fMRI of the temporal lobe of the awake monkey at 7 T

被引:24
作者
Goense, Jozien B. M. [1 ]
Ku, Shih-Pi [1 ]
Merkle, Hellmut [2 ]
Tolias, Andreas S. [1 ]
Logothetis, Nikos K. [1 ,3 ]
机构
[1] Max Planck Inst Biol Cybernet, Dept Physiol Cognit Proc, D-72076 Tubingen, Germany
[2] NINDS, Lab Funct & Mol Imaging, NIH, Bethesda, MD 20892 USA
[3] Univ Manchester, Manchester, Lancs, England
关键词
D O I
10.1016/j.neuroimage.2007.09.038
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Increasingly 7 T scanners are used for fMRI of humans and non-human primates, promising improvements in signal-to-noise, spatial resolution and specificity. A disadvantage of fMRI at 7 T, but already at 3 T, is that susceptibility artifacts from air-filled cavities like the ear canal and nasal cavity cause signal loss and distortion. This limits the applicability of fMRI in these areas, thereby limiting study of these areas, but it also limits study of processes that span large-scale cortical networks or the entire brain. Our goal is to study the inferior temporal (IT) lobe in awake monkeys because of its importance in object perception and recognition, but the functional signal is degraded by strong susceptibility gradients. To allow fMRI of this region, we used an optimized SE-EPI, which recovers signal lost with GE-EPI and we corrected for susceptibility-induced image distortion. SE-EPI has the added advantage that, in contrast to GE-EPI, where the functional signal derives to a large extent from veins, the SE-EPI signal arises from the microvasculature, and hence it better represents the neural activation. We show fMRI at 7 T of the entire visual pathway in the awake primate with robust and widespread activation in all ventral areas of the brain, including areas adjacent to the ear canal. This allows fMRI of areas that normally suffer from artifact and thus more reliable whole-brain studies. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:1081 / 1093
页数:13
相关论文
共 77 条
[1]  
Barfuss H, 1990, NMR Biomed, V3, P31, DOI 10.1002/nbm.1940030106
[2]   MR CONTRAST DUE TO INTRAVASCULAR MAGNETIC-SUSCEPTIBILITY PERTURBATIONS [J].
BOXERMAN, JL ;
HAMBERG, LM ;
ROSEN, BR ;
WEISSKOFF, RM .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) :555-566
[3]   Imaging cognition II: An empirical review of 275 PET and fMRI studies [J].
Cabeza, R ;
Nyberg, L .
JOURNAL OF COGNITIVE NEUROSCIENCE, 2000, 12 (01) :1-47
[4]   SUSCEPTIBILITY-LIMITED RESOLUTION IN NUCLEAR-MAGNETIC-RESONANCE MICROSCOPY [J].
CALLAGHAN, PT .
JOURNAL OF MAGNETIC RESONANCE, 1990, 87 (02) :304-318
[5]   AN ALGORITHM FOR NMR IMAGING RECONSTRUCTION BASED ON MULTIPLE RF RECEIVER COILS [J].
CARLSON, JW .
JOURNAL OF MAGNETIC RESONANCE, 1987, 74 (02) :376-380
[6]   A TECHNIQUE FOR ACCURATE MAGNETIC-RESONANCE-IMAGING IN THE PRESENCE OF FIELD INHOMOGENEITIES [J].
CHANG, H ;
FITZPATRICK, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (03) :319-329
[7]  
Conway BR, 2006, CEREB CORTEX, V16, P1604, DOI 10.1093/cercor/bhj099
[8]   An evaluation of the use of magnetic field maps to undistort echo-planar images [J].
Cusack, R ;
Brett, M ;
Osswald, K .
NEUROIMAGE, 2003, 18 (01) :127-142
[9]   New robust 3-D phase unwrapping algorithms: Application to magnetic field mapping and undistorting echoplanar images [J].
Cusack, R ;
Papadakis, N .
NEUROIMAGE, 2002, 16 (03) :754-764
[10]   Neural Mechanisms of Selective Visual Attention [J].
Moore, Tirin ;
Zirnsak, Marc .
ANNUAL REVIEW OF PSYCHOLOGY, VOL 68, 2017, 68 :47-72