fMRI of the temporal lobe of the awake monkey at 7 T

被引:24
作者
Goense, Jozien B. M. [1 ]
Ku, Shih-Pi [1 ]
Merkle, Hellmut [2 ]
Tolias, Andreas S. [1 ]
Logothetis, Nikos K. [1 ,3 ]
机构
[1] Max Planck Inst Biol Cybernet, Dept Physiol Cognit Proc, D-72076 Tubingen, Germany
[2] NINDS, Lab Funct & Mol Imaging, NIH, Bethesda, MD 20892 USA
[3] Univ Manchester, Manchester, Lancs, England
关键词
D O I
10.1016/j.neuroimage.2007.09.038
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Increasingly 7 T scanners are used for fMRI of humans and non-human primates, promising improvements in signal-to-noise, spatial resolution and specificity. A disadvantage of fMRI at 7 T, but already at 3 T, is that susceptibility artifacts from air-filled cavities like the ear canal and nasal cavity cause signal loss and distortion. This limits the applicability of fMRI in these areas, thereby limiting study of these areas, but it also limits study of processes that span large-scale cortical networks or the entire brain. Our goal is to study the inferior temporal (IT) lobe in awake monkeys because of its importance in object perception and recognition, but the functional signal is degraded by strong susceptibility gradients. To allow fMRI of this region, we used an optimized SE-EPI, which recovers signal lost with GE-EPI and we corrected for susceptibility-induced image distortion. SE-EPI has the added advantage that, in contrast to GE-EPI, where the functional signal derives to a large extent from veins, the SE-EPI signal arises from the microvasculature, and hence it better represents the neural activation. We show fMRI at 7 T of the entire visual pathway in the awake primate with robust and widespread activation in all ventral areas of the brain, including areas adjacent to the ear canal. This allows fMRI of areas that normally suffer from artifact and thus more reliable whole-brain studies. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:1081 / 1093
页数:13
相关论文
共 77 条
[51]   Anatomical and functional MR imaging in the macaque monkey using a vertical large-bore 7 Tesla setup [J].
Pfeuffer, J ;
Merkle, H ;
Beyerlein, M ;
Steudel, T ;
Logothetis, NK .
MAGNETIC RESONANCE IMAGING, 2004, 22 (10) :1343-1359
[52]   Functional MR imaging in the awake monkey: effects of motion on dynamic off-resonance and processing strategies [J].
Pfeuffer, Josef ;
Shmuel, Amir ;
Keliris, Georgios A. ;
Steudel, Thomas ;
Merkle, Hellmut ;
Logothetis, Nikos K. .
MAGNETIC RESONANCE IMAGING, 2007, 25 (06) :869-882
[53]   Representations of faces and body parts in macaque temporal cortex: A functional MRI study [J].
Pinsk, MA ;
DeSimone, K ;
Moore, T ;
Gross, CG ;
Kastner, S .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2005, 102 (19) :6996-7001
[54]  
Pruessmann KP, 1999, MAGNET RESON MED, V42, P952, DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO
[55]  
2-S
[56]   THE NMR PHASED-ARRAY [J].
ROEMER, PB ;
EDELSTEIN, WA ;
HAYES, CE ;
SOUZA, SP ;
MUELLER, OM .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) :192-225
[57]   Comparison of fMRI activation as measured with gradient- and spin-echo EPI during visual perception [J].
Schmidt, CF ;
Boesiger, P ;
Ishai, A .
NEUROIMAGE, 2005, 26 (03) :852-859
[58]   Sensitivity-encoded (SENSE) echo planar fMRI at 3T in the medial temporal lobe [J].
Schmidt, CF ;
Degonda, N ;
Luechinger, R ;
Henke, K ;
Boesiger, P .
NEUROIMAGE, 2005, 25 (02) :625-641
[59]   Advances in functional and structural MR image analysis and implementation as FSL [J].
Smith, SM ;
Jenkinson, M ;
Woolrich, MW ;
Beckmann, CF ;
Behrens, TEJ ;
Johansen-Berg, H ;
Bannister, PR ;
De Luca, M ;
Drobnjak, I ;
Flitney, DE ;
Niazy, RK ;
Saunders, J ;
Vickers, J ;
Zhang, YY ;
De Stefano, N ;
Brady, JM ;
Matthews, PM .
NEUROIMAGE, 2004, 23 :S208-S219
[60]   Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays [J].
Sodickson, DK ;
Manning, WJ .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (04) :591-603