Functional MR imaging in the awake monkey: effects of motion on dynamic off-resonance and processing strategies

被引:23
作者
Pfeuffer, Josef
Shmuel, Amir
Keliris, Georgios A.
Steudel, Thomas
Merkle, Hellmut
Logothetis, Nikos K.
机构
[1] Siemens Med Solut, MR Applicat Dev, D-91052 Erlangen, Germany
[2] Max Planck Inst Biol Cybernet, Dept Physiol Cognit Proc, D-72076 Tubingen, Germany
[3] NINDS, Lab Funct & Mol Imaging, NIH, Bethesda, MD 20892 USA
关键词
functional imaging; monkey brain; high-field MR system;
D O I
10.1016/j.mri.2007.03.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Functional MR imaging of the alert, behaving monkey is being used more and more often to detect activation patterns and guide electrophysiological research investigating the neural basis of behavior. Several labs have reported fMRI data from the awake monkey, but none of them has studied and systematically corrected the effects of monkeys' motion on fMRI time series. In this study, a significant refinement of acquisition and correction strategies is reported that can be used to minimize magnetic susceptibility artifacts induced by respiration and by jaw and body movement. Real-time acquisition of sensor signals (e.g., signals induced by jaw and body movement) and MR navigator data were combined to optimize fMRI signal-correction strategies. Within trials, the artifact-induced off-resonance changes were small and mainly reflected the effects of respiration; between trials, movements caused major changes of global frequency and shim (> 20 Hz/cm). Several methods were used to assess the stability of the fMRI series: k-space analysis ('dynamic intensity and off-resonance changes in k-space', dubbed DICK and DORK) and image analysis using a Laplace operator and a center-of-mass metric. The variability between trials made it essential to correct for inter-trial variations. On the other hand, images were sufficiently stable with our approach to perform fMRI evaluations on single trials before averaging of trials. Different motion correction strategies were compared: DORK, McFLIRT (rigid body model with three translations and three rotations) and 2D image alignment based on a center-of-mass detection (in-plane translation). The latter yielded the best results and proved to be fast and robust for intra- and inter-trial alignment. Finally, fMRI in the behaving monkey was tested for spatial and temporal reproducibility on a trial-to-trial basis. Highly activated voxels also displayed good reproducibility between trials. On average, the BOLD amplitude response to a short 3-s visual stimulus was close to 2%. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:869 / 882
页数:14
相关论文
共 32 条
[1]  
Biswal BB, 1997, NMR BIOMED, V10, P165, DOI 10.1002/(SICI)1099-1492(199706/08)10:4/5<165::AID-NBM454>3.0.CO
[2]  
2-7
[3]  
Dold C, 2005, LECT NOTES COMPUT SC, V3749, P482
[4]   Functional magnetic resonance imaging: A review of methodological aspects and clinical applications [J].
Hennig, J ;
Speck, O ;
Koch, MA ;
Weiller, C .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (01) :1-15
[5]   Image distortion correction in fMRI: A quantitative evaluation [J].
Hutton, C ;
Bork, A ;
Josephs, O ;
Deichmann, R ;
Ashburner, J ;
Turner, R .
NEUROIMAGE, 2002, 16 (01) :217-240
[6]   Improved optimization for the robust and accurate linear registration and motion correction of brain images [J].
Jenkinson, M ;
Bannister, P ;
Brady, M ;
Smith, S .
NEUROIMAGE, 2002, 17 (02) :825-841
[7]  
Jezzard P, 1999, HUM BRAIN MAPP, V8, P80, DOI 10.1002/(SICI)1097-0193(1999)8:2/3<80::AID-HBM2>3.0.CO
[8]  
2-C
[9]   Robust controlled functional MRI in alert monkeys at high magnetic field: Effects of jaw and body movements [J].
Keliris, Georgios A. ;
Shmuel, Amir ;
Ku, Shih-Pi ;
Pfeuffer, Josef ;
Oeltermann, Axel ;
Steudel, Thomas ;
Logothetis, Nikos K. .
NEUROIMAGE, 2007, 36 (03) :550-570
[10]   Neuroimaging at 1.5 T and 3.0 T:: Comparison of oxygenation-sensitive magnetic resonance imaging [J].
Krüger, G ;
Kastrup, A ;
Glover, GH .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :595-604