Functional MR imaging in the awake monkey: effects of motion on dynamic off-resonance and processing strategies

被引:23
作者
Pfeuffer, Josef
Shmuel, Amir
Keliris, Georgios A.
Steudel, Thomas
Merkle, Hellmut
Logothetis, Nikos K.
机构
[1] Siemens Med Solut, MR Applicat Dev, D-91052 Erlangen, Germany
[2] Max Planck Inst Biol Cybernet, Dept Physiol Cognit Proc, D-72076 Tubingen, Germany
[3] NINDS, Lab Funct & Mol Imaging, NIH, Bethesda, MD 20892 USA
关键词
functional imaging; monkey brain; high-field MR system;
D O I
10.1016/j.mri.2007.03.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Functional MR imaging of the alert, behaving monkey is being used more and more often to detect activation patterns and guide electrophysiological research investigating the neural basis of behavior. Several labs have reported fMRI data from the awake monkey, but none of them has studied and systematically corrected the effects of monkeys' motion on fMRI time series. In this study, a significant refinement of acquisition and correction strategies is reported that can be used to minimize magnetic susceptibility artifacts induced by respiration and by jaw and body movement. Real-time acquisition of sensor signals (e.g., signals induced by jaw and body movement) and MR navigator data were combined to optimize fMRI signal-correction strategies. Within trials, the artifact-induced off-resonance changes were small and mainly reflected the effects of respiration; between trials, movements caused major changes of global frequency and shim (> 20 Hz/cm). Several methods were used to assess the stability of the fMRI series: k-space analysis ('dynamic intensity and off-resonance changes in k-space', dubbed DICK and DORK) and image analysis using a Laplace operator and a center-of-mass metric. The variability between trials made it essential to correct for inter-trial variations. On the other hand, images were sufficiently stable with our approach to perform fMRI evaluations on single trials before averaging of trials. Different motion correction strategies were compared: DORK, McFLIRT (rigid body model with three translations and three rotations) and 2D image alignment based on a center-of-mass detection (in-plane translation). The latter yielded the best results and proved to be fast and robust for intra- and inter-trial alignment. Finally, fMRI in the behaving monkey was tested for spatial and temporal reproducibility on a trial-to-trial basis. Highly activated voxels also displayed good reproducibility between trials. On average, the BOLD amplitude response to a short 3-s visual stimulus was close to 2%. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:869 / 882
页数:14
相关论文
共 32 条
[21]  
PFEUFFER J, 2006, P INT SOC MAG RES ME, P2841
[22]  
PFEUFFER J, 2003, P ISMRM 11 SCI M TOR, P1781
[23]   A model for susceptibility artefacts from respiration in functional echo-planar magnetic resonance imaging [J].
Raj, D ;
Paley, DP ;
Anderson, AW ;
Kennan, RP ;
Gore, JC .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (12) :3809-3820
[24]   Hardware considerations for functional magnetic resonance imaging [J].
Silva, AC ;
Merkle, H .
CONCEPTS IN MAGNETIC RESONANCE PART A, 2003, 16A (01) :35-49
[25]  
Thesen S, 2000, MAGNET RESON MED, V44, P457, DOI 10.1002/1522-2594(200009)44:3<457::AID-MRM17>3.0.CO
[26]  
2-R
[27]   Functional magnetic resonance imaging of the human brain: data acquisition and analysis [J].
Turner, R ;
Howseman, A ;
Rees, GE ;
Josephs, O ;
Friston, K .
EXPERIMENTAL BRAIN RESEARCH, 1998, 123 (1-2) :5-12
[28]   Ultrahigh field magnetic resonance imaging and spectroscopy [J].
Ugurbil, K ;
Adriany, G ;
Andersen, P ;
Chen, W ;
Garwood, M ;
Gruetter, R ;
Henry, PG ;
Kim, SG ;
Lieu, H ;
Tkac, I ;
Vaughan, T ;
Van de Moortele, PF ;
Yacoub, E ;
Zhu, XH .
MAGNETIC RESONANCE IMAGING, 2003, 21 (10) :1263-1281
[29]   Respiration-induced B0 fluctuations and their spatial distribution in the human brain at 7 tesla [J].
Van de Moortele, PF ;
Pfeuffer, J ;
Glover, GH ;
Ugurbil, K ;
Hu, XP .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (05) :888-895
[30]   Real-time autoshimming for echo planar timecourse imaging [J].
Ward, HA ;
Riederer, SJ ;
Jack, CR .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (05) :771-780