Real-time autoshimming for echo planar timecourse imaging

被引:71
作者
Ward, HA [1 ]
Riederer, SJ [1 ]
Jack, CR [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Dept Radiol, Rochester, MN 55905 USA
关键词
functional magnetic resonance imaging; navigator echoes; motion correction; EPI artifact; real-time MRI; B-0; stability;
D O I
10.1002/mrm.10259
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Head motion within an applied magnetic field alters the effective shim within the brain, causing geometric distortions in echo planar imaging (EPI). Even if subtle, change in shim can lead to artifactual signal changes in timecourse EPI acquisitions, which are typically performed for functional MRI (fMRI) or diffusion tensor imaging. Magnetic field maps acquired before and after head motions of clinically realistic magnitude indicate that motion-induced changes in magnetic field may cause translations exceeding 3 mm in the phase-encoding direction of the EPI images. The field maps also demonstrate a trend toward linear variations in shim changes as a function of position within the head, suggesting that a real-time, first-order correction may compensate for motion-induced changes in magnetic field. This article presents a navigator pulse sequence and processing method, termed a "shim NAV," for real-time detection of linear shim changes, and a shim-compensated EPI pulse sequence for dynamic correction of linear shim changes. In vivo and phantom experiments demonstrate the detection accuracy of shim NAVs in the presence of applied gradient shims. Phantom experiments demonstrate reduction of geometric distortion and image artifact using shim-compensated EPI in the presence of applied gradient shims. In vivo experiments with intentional inter-image subject motion demonstrate improved alignment of timecourse EPI images when using the shim NAV-detected values to update the shim-compensated EPI acquisition in real time. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:771 / 780
页数:10
相关论文
共 28 条
[1]   Modeling geometric deformations in EPI time series [J].
Andersson, JLR ;
Hutton, C ;
Ashburner, J ;
Turner, R ;
Friston, K .
NEUROIMAGE, 2001, 13 (05) :903-919
[2]  
BIRN RM, 1997, P ISMRM 5 ANN M VANC, P1913
[3]  
BIRN RM, 1998, P ISMRM 6 ANN M SYDN, P716
[4]  
Cox RW, 1999, MAGNET RESON MED, V42, P1014, DOI 10.1002/(SICI)1522-2594(199912)42:6<1014::AID-MRM4>3.0.CO
[5]  
2-F
[6]   AFNI: Software for analysis and visualization of functional magnetic resonance neuroimages [J].
Cox, RW .
COMPUTERS AND BIOMEDICAL RESEARCH, 1996, 29 (03) :162-173
[7]  
Deichmann R, 2001, NEUROIMAGE, V13, pS8
[8]   Dynamic scan-plane tracking using MR position monitoring [J].
Derbyshire, JA ;
Wright, GA ;
Henkelman, RM ;
Hinks, RS .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (04) :924-932
[9]   ADAPTIVE TECHNIQUE FOR HIGH-DEFINITION MR IMAGING OF MOVING STRUCTURES [J].
EHMAN, RL ;
FELMLEE, JP .
RADIOLOGY, 1989, 173 (01) :255-263
[10]   ANALYSIS OF T2 LIMITATIONS AND OFF-RESONANCE EFFECTS ON SPATIAL-RESOLUTION AND ARTIFACTS IN ECHO-PLANAR IMAGING [J].
FARZANEH, F ;
RIEDERER, SJ ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) :123-139