In vitro mechanical integrity of hydroxyapatite coated magnesium alloy

被引:58
作者
Kannan, M. Bobby [1 ]
Orr, Lynnley [1 ]
机构
[1] James Cook Univ, Sch Engn & Phys Sci, Discipline Chem Engn, Townsville, Qld 4811, Australia
关键词
STRESS-CORROSION CRACKING; RARE-EARTH; ELECTRODEPOSITION; DEGRADATION; COATINGS;
D O I
10.1088/1748-6041/6/4/045003
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
The mechanical integrity of resorbable implants during service, especially in load bearing orthopaedic applications, is critical. The high degradation rate of resorbable magnesium and magnesium-based implants in body fluid may potentially cause premature in-service failure. In this study, a magnesium alloy (AZ91) was potentiostatically coated with hydroxyapatite at different cathodic voltages in an attempt to enhance the mechanical integrity. The mechanical integrity of the uncoated and hydroxyapatite coated alloys was evaluated after in vitro testing of the coated samples in simulated body fluid (SBF). The uncoated alloy showed 40% loss in the mechanical strength after five days exposure to SBF. However, the hydroxyapatite coated alloy exposed to SBF showed 20% improvement in the mechanical strength as compared to that of the uncoated alloy. The alloy coated potentiostatically at -2 V performed better than the -3 V coated alloy. The cross-sectional analysis of the coatings revealed relatively uniform coating thickness for the -2 V coated alloy, whereas the -3 V coated alloy exhibited areas of uneven coating. This can be attributed to the increase in hydrogen evolution on the alloy during -3 V coating as compared to -2 V coating. The scanning electron micrographs of the in vitro tested alloy revealed that hydroxyapatite coating significantly reduced the localized corrosion of the alloy, which is critical for better in-service mechanical integrity. Thus, the study suggests that the in vitro mechanical integrity of resorbable magnesium-based alloy can be improved by potentiostatic hydroxyapatite coating.
引用
收藏
页数:11
相关论文
共 33 条
[1]
Bioceramics: Past, present and for the future [J].
Best, S. M. ;
Porter, A. E. ;
Thian, E. S. ;
Huang, J. .
JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2008, 28 (07) :1319-1327
[2]
Dumelie H., 2008, MATER CHARACT, V59, P129
[3]
New emerging trends in synthetic biodegradable polymers - Polylactide: A critique [J].
Gupta, A. P. ;
Kumar, Vimal .
EUROPEAN POLYMER JOURNAL, 2007, 43 (10) :4053-4074
[4]
Ishikawa K, 1997, J BIOMED MATER RES, V38, P129, DOI 10.1002/(SICI)1097-4636(199722)38:2<129::AID-JBM7>3.0.CO
[5]
2-S
[6]
Metal degradation products - A cause for concern in metal-metal bearings? [J].
Jacobs, JJ ;
Hallab, NJ ;
Skipor, AK ;
Urban, RM .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (417) :139-147
[7]
Corrosion of metal orthopaedic implants [J].
Jacobs, JJ ;
Gilbert, JL ;
Urban, RM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (02) :268-282
[8]
Evaluating the stress corrosion cracking susceptibility of Mg-Al-Zn alloy in modified-simulated body fluid for orthopaedic implant application [J].
Kannan, M. Bobby ;
Raman, R. K. Singh .
SCRIPTA MATERIALIA, 2008, 59 (02) :175-178
[9]
Stress corrosion cracking of rare-earth containing magnesium alloys ZE41, QE22 and Elektron 21 (EV31A) compared with AZ80 [J].
Kannan, M. Bobby ;
Dietzel, W. ;
Blawert, C. ;
Atrens, A. ;
Lyon, P. .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2008, 480 (1-2) :529-539
[10]
In vitro degradation and mechanical integrity of calcium-containing magnesium alloys in modified-simulated body fluid [J].
Kannan, M. Bobby ;
Raman, R. K. Singh .
BIOMATERIALS, 2008, 29 (15) :2306-2314