Metal degradation products - A cause for concern in metal-metal bearings?

被引:171
作者
Jacobs, JJ [1 ]
Hallab, NJ [1 ]
Skipor, AK [1 ]
Urban, RM [1 ]
机构
[1] Rush Univ, Dept Orthoped Surg, Rush Med Coll, Chicago, IL 60612 USA
关键词
D O I
10.1097/01.blo.0000096810.78689.62
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In the majority of patients, orthopaedic implants are biocompatible. However, there is an increasing recognition that, in the long-term, permanent orthopaedic implants may be associated with adverse local and remote tissue responses in some individuals. These adverse effects are mediated by the degradation products of implant materials. The recent reintroduction of metal-on-metal bearings for total hip arthroplasty has heightened concerns about the biologic response to metal degradation products in light of the fact that the serum and urine metal concentrations in patients with these implants typically are higher than those seen in patients with conventional metal-on-polyethylene bearings. From previous studies of long-term metal-on-metal McKee-Farrar implants, it seems that these elevated levels may persist for the duration of the implant's lifetime. This is of particular concern in the younger and more active patient in whom life expectancy after implantation may exceed 30 years. The association of metal release from orthopaedic implants with any metabolic, bacteriologic, immunologic, or carcinogenic toxicity currently remains conjectural because cause and effect have not been established in human subjects. However, continued surveillance of patient populations with metal implants, particularly those with metal-metal bearings, is warranted.
引用
收藏
页码:139 / 147
页数:9
相关论文
共 46 条
[1]
[Anonymous], OSTEOLOGIE
[2]
BLACK J, 1998, ORTHOPAEDIC BIOMATER, P292
[3]
Elevated serum cobalt with metal-on-metal articulating surfaces [J].
Brodner, W ;
Bitzan, P ;
Meisinger, V ;
Kaider, A ;
GottsaunerWolf, F ;
Kotz, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (02) :316-321
[4]
CONCENTRATION OF WEAR PRODUCTS IN HAIR, BLOOD, AND URINE AFTER TOTAL HIP REPLACEMENT [J].
COLEMAN, RF ;
HERRINGTON, J ;
SCALES, JT .
BMJ-BRITISH MEDICAL JOURNAL, 1973, 1 (5852) :527-529
[5]
CORROSION BETWEEN THE COMPONENTS OF MODULAR FEMORAL HIP PROSTHESES [J].
COLLIER, JP ;
SURPRENANT, VA ;
JENSEN, RE ;
MAYOR, MB ;
SURPRENANT, HP .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (04) :511-517
[6]
Doorn PF, 1998, J BIOMED MATER RES, V42, P103, DOI 10.1002/(SICI)1097-4636(199810)42:1<103::AID-JBM13>3.3.CO
[7]
2-D
[8]
DOORN PF, 1996, CLIN ORTHOP S, V329, pS187
[9]
Elinder CG, 1986, HDB TOXICOLOGY METAL, P211
[10]
IN-VIVO CORROSION OF MODULAR HIP-PROSTHESIS COMPONENTS IN MIXED AND SIMILAR METAL COMBINATIONS - THE EFFECT OF CREVICE, STRESS, MOTION, AND ALLOY COUPLING [J].
GILBERT, JL ;
BUCKLEY, CA ;
JACOBS, JJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (12) :1533-1544