Comparative analysis of osseointegration in various types of acetabular implant materials

被引:21
作者
Bondarenko, Stanislav [1 ]
Dedukh, Ninel [1 ]
Filipenko, Volodymyr [1 ]
Akonjom, Mandus [1 ]
Badnaoui, Ahmed Amine [1 ]
Schwarzkopf, Ran [2 ]
机构
[1] Natl Acad Med Sci Ukraine, Sytenko Inst Spine & Joint Pathol, Kharkov, Ukraine
[2] NYU, Langone Med Ctr, Hosp Joint Dis, New York, NY USA
关键词
Acetabular implants; Bone-to-implant contact; Morphology; Rats; Trabecular Titanium; Trabecular Tantalum; TOTAL HIP-ARTHROPLASTY; POROUS TANTALUM BIOMATERIAL; LOW-FRICTION ARTHROPLASTY; BONE-MINERAL DENSITY; FOLLOW-UP; IN-VIVO; OSTEOPOROSIS; MINIMUM; REPLACEMENT; OSTEOINTEGRATION;
D O I
10.1177/1120700018759314
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: There is a lack of comparative data on osseointegration (BIC) of acetabular cup surfaces in hip arthroplasty in both normal bone mineral density and in conditions of osteoporosis. Aim: To compare osseointegration of acetabular implants with various types of surfaces in an animal model with normal and osteoporotic bone tissue. Material and Methods: The study was performed on 60 rats. To simulate osteoporosis ovariectomy was performed in 30 animals. Thirty healthy rats served as controls. In standardised defects of the distal metadiaphysis of the femur we implanted: porous tantalum Trabecular Metal (A), Trabecular Titanium (B), Titanium with Gription coating (C), Stiktite (D), and Tritanum (E). Bone apposition (osseointegration) was defined as all areas of direct "bone-to-implant contact" (BIC). Results: No qualitative morphological differences in the evaluation of BIC around different implant types was seen in normal rats and rats with osteoporosis. Connective tissue areas around implants were larger in rats with osteoporosis. Morphometric studies showed that the highest BIC were seen in implants A and B, both in healthy animals ([72.00 +/- 3.48]% and [67.46 +/- 1.69]%) and ones with osteoporosis ([59.19 +/- 2.10]% and [53.36 +/- 2.57]%). BIC was (60.10 +/- 2.05)%, (60.26 +/- 2.36)%, and (61.78 +/- 2.27)% around implants C, D and E in healthy rats, respectively. BIC in osteoporosis was (45.39 +/- 2.37)%, (47.81 +/- 2.41)% and (42.10 +/- I .44)%, respectively. Conclusion: Our study showed that the evaluated implants have good BIC features. Furthermore, based on histomorthometry and histology, Porous tantalum Trabecular Metal (A) and Trabecular Titanium (B) implants exhibit higher BIC with bone tissue.
引用
收藏
页码:622 / 628
页数:7
相关论文
共 43 条
[21]
Lelovas PP, 2008, COMPARATIVE MED, V58, P424
[22]
Charnley total hip arthroplasty with use of improved techniques of cementing - The results after a minimum of fifteen years of follow-up [J].
Madey, SM ;
Callaghan, JJ ;
Olejniczak, JP ;
Goetz, DD ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (01) :53-64
[23]
The incidence of osteopenia and osteoporosis in women with hip osteoarthritis scheduled for cementless total joint replacement [J].
Makinen, Tatu J. ;
Alm, Jessica J. ;
Laine, Hanna ;
Svedstrom, Erkki ;
Aro, Hannu T. .
BONE, 2007, 40 (04) :1041-1047
[24]
PROGNOSIS OF TOTAL HIP-REPLACEMENT IN SWEDEN - FOLLOW-UP OF 92,675 OPERATIONS PERFORMED 1978-1990 [J].
MALCHAU, H ;
HERBERTS, P ;
AHNFELT, L .
ACTA ORTHOPAEDICA SCANDINAVICA, 1993, 64 (05) :497-506
[25]
Bone response adjacent to calcium phosphate electrostatic spray deposition coated implants: an experimental study in goats [J].
Manders, Peter J. D. ;
Wolke, Joop G. C. ;
Jansen, John A. .
CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (05) :548-553
[26]
Marin E., 2010, European Orthopaedics and Traumatology, V1, P103
[27]
Mavrogenis AF, 2009, J MUSCULOSKEL NEURON, V9, P61
[28]
A comparison of hydroxyapatite-coated, titanium-coated, and uncoated tapered external-fixation pins -: An in vivo study in sheep [J].
Moroni, A ;
Toksvig-Larsen, S ;
Maltarello, MC ;
Orienti, L ;
Stea, S ;
Giannini, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (04) :547-554
[29]
Excellent Results of Primary THA Using a Highly Porous Titanium Cup [J].
Naziri, Qais ;
Issa, Kimona ;
Pivec, Robert ;
Harwin, Steven F. ;
Delanois, Ronald E. ;
Mont, Michael A. .
ORTHOPEDICS, 2013, 36 (04) :E390-E394
[30]
Titanium oral implants: surface characteristics, interface biology and clinical outcome [J].
Palmquist, Anders ;
Omar, Omar M. ;
Esposito, Marco ;
Lausmaa, Jukka ;
Thomsen, Peter .
JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2010, 7 :S515-S527