Blood flow quantification in haemodialysis fistulae by phase contrast MR angiography (PC-MRA) in comparison to duplex sonography.

被引:9
作者
Gutberlet, M
Venz, S
Kahl, A
Ehrenstein, T
Puls, R
Hosten, N
Frei, U
Felix, R
机构
[1] Humboldt Universitat Berlin, Strahlenklin & Poliklin, Fak Med, D-13353 Berlin, Germany
[2] Humboldt Universitat Berlin, Abt Innere Med Nephrol & Intens Med, Fak Med, D-13353 Berlin, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 1998年 / 169卷 / 02期
关键词
phase contrast angiography; magnetic resonance imaging; haemodialysis fistulae; flow measurements; colour Duplex sonography;
D O I
10.1055/s-2007-1015068
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Aim of this study was to evaluate whether phase contrast MR angiography (PC-MRA) could provide additional functional information besides morphology in the assessment of haemodialysis fistulae. Material and method: Twenty-two patients (11 male, 11 female), aged 22-77 years, were examined. MR images were obtained with a 1.5 T Gyroscan(R) ACS-NT (Philips, Best, Netherlands) using a high-resolution wrap-around coil. In addition to MRA blood-flow measurements were performed with a gradient-echo sequence (T-R 14 ms, T-E 5-5.5 ms, flip-angle 15 degrees, 6 mm slice thickness, retrospective gating, matrix 96:128) in the venous and arterial section of the fistulae. Doppler flow measurements were performed at the same position with a Sonoline Elegra(R) (Siemens AC, Erlangen) using a 7.5 MHz transducer. Results: Both methods of flow-volume measurements showed a good correlation (r = 0.94 in the arterial section, r = 0.90 in the venous section, p<0.001). The average calculated blood flow was measured 11%(arterial section) and 12.8% (venous section) higher with Pulsed Waved Doppler as compared to PC-MRA. Conclusion: PC-MRA with a high-resolution wrap-around coil is a reliable method for measuring functional parameters like flow-volume and flow velocity in haemodialysis fistulae and a useful complement to the visualisation capabilities of MRA.
引用
收藏
页码:163 / 169
页数:7
相关论文
共 30 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
BOECK JC, 1991, ROFO FORTSCHR RONTG, V155, P267
[3]  
BORELLO JA, 1995, RADIOLOGY, V197, P793
[4]   IMPROVED SURFACE COIL IMAGING IN MR - DECOUPLING OF THE EXCITATION AND RECEIVER COILS [J].
BOSKAMP, EB .
RADIOLOGY, 1985, 157 (02) :449-452
[5]  
Bosman PJ, 1996, J AM SOC NEPHROL, V7, P966
[6]  
BRUCHER J, 1986, MED PHYSIK 1986, P375
[7]   HEMODIALYSIS GRAFTS - COLOR DOPPLER FLOW IMAGING CORRELATED WITH DIGITAL SUBTRACTION ANGIOGRAPHY AND FUNCTIONAL STATUS [J].
DOUSSET, V ;
GRENIER, N ;
DOUWS, C ;
SENUITA, P ;
SASSOUSTE, G ;
ADA, L ;
POTAUX, L .
RADIOLOGY, 1991, 181 (01) :89-94
[8]   THE APPLICATION OF PHASE-SHIFTS IN NMR FOR FLOW MEASUREMENT [J].
FIRMIN, DN ;
NAYLER, GL ;
KILNER, PJ ;
LONGMORE, DB .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) :230-241
[9]   IMAGING OF HEMODIALYSIS FISTULAS - LIMITATIONS OF MR ANGIOGRAPHY [J].
GEHL, HB ;
BOHNDORF, K ;
GLADZIWA, U ;
HANDT, S ;
GUNTHER, RW .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (02) :271-275
[10]   DIALYSIS ACCESS FISTULAS - TREATMENT OF STENOSES BY TRANS-LUMINAL ANGIOPLASTY [J].
GLANZ, S ;
GORDON, D ;
BUTT, KMH ;
HONG, J ;
ADAMSON, R ;
SCLAFANI, SJA .
RADIOLOGY, 1984, 152 (03) :637-642