Simple charge division readouts for imaging scintillator arrays using a multi-channel PMT

被引:255
作者
Siegel, S
Silverman, RW
Shao, YP
Cherry, SR
机构
[1] Crump Institute for Biological Imaging, UCLA School of Medicine, Los Angeles, CA
基金
美国国家卫生研究院;
关键词
D O I
10.1109/23.507162
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Three simple charge division circuits were assembled and tested as 2-D position encoding readouts for multi-channel photomultiplier tubes (MC-PMT). They were evaluated with an 8x8 array of individual scintillators (2x2x10 mm EGO) coupled to a 64 channel MC-PMT (Philips XP1722) via 25 cm long, 2 mm diameter, double clad, optical fibers (Kuraray). This type of gamma-ray imaging detector has many potential applications in medical and industrial imaging. Though independent channel readout would allow for the discrimination of scatter within the array, and higher count rates, it would also require an excessive amount of supporting electronics. This is especially true for systems comprised of many MC-PMTs. In this study, the number of channels being read out was reduced from 63 to 4 using three different simple resistor networks. These circuits take advantage of the discretized nature of the scintillator array, the low interchannel crosstalk of the MC-PMT and low input impedance current-sensitive preamplifiers. For each circuit, the scintillator identification accuracy was compared. The identification accuracy as a function of deposited energy was also determined by exposure to various gamma-ray emitters. It was found preamplifier circuit noise contributed the most degradation of the detector's spatial response so several low noise op amps were evaluated. It was also determined that keeping the preamplifier input impedance small was necessary for accurate positioning. The coincidence timing resolution of the detector (15 ns) is only slightly degraded by the readout circuit.
引用
收藏
页码:1634 / 1641
页数:8
相关论文
共 9 条
[1]   SCINTILLATION CAMERA [J].
ANGER, HO .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1958, 29 (01) :27-33
[2]   SOME APPLICATIONS AND PROPERTIES OF ONE-DIMENSIONAL AND TWO-DIMENSIONAL POSITION-SENSITIVE PROPORTIONAL COUNTERS [J].
BORKOWSKI, CJ ;
KOPP, MK .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1970, NS17 (03) :340-+
[3]   COLLECTION OF SCINTILLATION LIGHT FROM SMALL BGO CRYSTALS [J].
CHERRY, SR ;
SHAO, YP ;
TORNAI, MP ;
SIEGEL, S ;
RICCI, AR ;
PHELPS, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :1058-1063
[4]  
CHERRY SR, 1996, IN RPESS IEEE T NUC
[5]   TEST OF A NEW 64-CHANNEL PMT FOR IMAGING [J].
COMBY, G ;
MEUNIER, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 269 (01) :246-260
[6]   USE OF DIGITAL FRONT-END ELECTRONICS FOR OPTIMIZATION OF A MODULAR PET DETECTOR [J].
CUTLER, PD ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (02) :408-418
[8]  
MOYERS JC, 1990, THESIS U TENNESSEE K
[9]  
TORNAI MP, 1996, IN PRESS IEEE T NUC