Four-dimensional MR microscopy of the mouse heart using radial acquisition and liposomal gadolinium contrast agent

被引:35
作者
Bucholz, Elizabeth [1 ,2 ]
Ghaghada, Ketan [1 ]
Qi, Yi [1 ]
Mukundan, Srinivasan [1 ,2 ,3 ]
Johnson, G. Allan [1 ,2 ,3 ]
机构
[1] Duke Univ, Med Ctr, Ctr Vivo Microscopy, Durham, NC 27710 USA
[2] Duke Univ, Dept Biomed Engn, Durham, NC 27710 USA
[3] Duke Univ, Dept Radiol, Durham, NC 27710 USA
关键词
4D; radial; mouse; heart; liposomal Gd;
D O I
10.1002/mrm.21618
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance microscopy (MRM) has become an important tool for small animal cardiac imaging. In relation to competing technologies (microCT and ultrasound), MR is limited by spatial resolution, temporal resolution, and acquisition time. All three of these limitations have been addressed by developing a four-dimensional (4D) (3D plus time) radial acquisition (RA) sequence. The signal-to-noise ratio (SNR) has been optimized by minimizing the echo time (TE) (300 us). The temporal resolution and throughput have been improved by center-out trajectories resulting in repetition time (TR) < 2.5 ms. The contrast has been enhanced through the use of a liposomal blood pool agent that reduces the T, of the blood to < 400 ms. We have developed protocols for three specific applications: 1) high-throughput with spatial resolution of 87 X 87 x 352 um(3) (voxel volume = 2.7 nL) and acquisition time of 16 min; 2) high-temporal resolution with spatial resolution of 87 x 87 x 352 um(3) (voxel volume = 2.7 nL) and temporal resolution at 4.8 ms and acquisition time of 32 minutes; and 3) high-resolution isotropic imaging at 87 x 87 x 87 um(3) (voxel volume = 0.68 nL) and acquisition time of 31 min. The 4D image arrays allow direct measure of cardiac functional parameters dependent on chamber volumes, e.g., ejection fraction (EF), end diastolic volume (EDV), and end systolic volume (ESV).
引用
收藏
页码:111 / 118
页数:8
相关论文
共 38 条
[1]  
Amano Y, 2000, JMRI-J MAGN RESON IM, V11, P81, DOI 10.1002/(SICI)1522-2586(200002)11:2<81::AID-JMRI2>3.0.CO
[2]  
2-N
[3]  
Badea C.T., 2005, Molecular Imaging, V4, DOI [10.1162/15353500200504187, DOI 10.1162/15353500200504187]
[4]  
Barger AV, 2000, MAGNET RESON MED, V44, P821, DOI 10.1002/1522-2594(200012)44:6<821::AID-MRM1>3.0.CO
[5]  
2-S
[6]   Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory [J].
Barger, AV ;
Block, WF ;
Toropov, Y ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) :297-305
[7]  
Bernstein MA, 2004, HDB MRI PULSE SEQUEN, P616
[8]   Black blood gradient echo cine magnetic resonance imaging of the mouse heart [J].
Berr, SS ;
Roy, RJ ;
French, BA ;
Yang, ZQ ;
Gilson, W ;
Kramer, CM ;
Epstein, FH .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (05) :1074-1079
[9]   Cine magnetic resonance microscopy of the rat heart using cardiorespiratory-synchronous projection reconstruction [J].
Brau, ACS ;
Hedlund, LW ;
Johnson, GA .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (01) :31-38
[10]   Assessment of motion gating strategies for mouse magnetic resonance at high magnetic fields [J].
Cassidy, PJ ;
Schneider, JE ;
Grieve, SM ;
Lygate, C ;
Neubauer, S ;
Clarke, K .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (02) :229-237