Black blood gradient echo cine magnetic resonance imaging of the mouse heart

被引:53
作者
Berr, SS
Roy, RJ
French, BA
Yang, ZQ
Gilson, W
Kramer, CM
Epstein, FH [1 ]
机构
[1] Univ Virginia, Dept Radiol, Charlottesville, VA USA
[2] Univ Virginia, Dept Biomed Engn, Charlottesville, VA USA
[3] Univ Virginia, Dept Cardiovasc Res Ctr, Charlottesville, VA USA
[4] Univ Virginia, Dept Med, Charlottesville, VA USA
关键词
MRI; mice; heart; cardiac; black blood;
D O I
10.1002/mrm.20487
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
A black blood gradient echo sequence for multiphase cardiac MRI of the mouse heart was implemented on a 4.7-T scanner and compared to a conventional bright blood sequence. Black blood was achieved using the double inversion recovery technique. Ten mice were imaged using both the bright and the black blood sequences, and 2 of the mice were additionally imaged using bright and black blood sequences modified to perform myocardial tagging. Manual planimetry of the images was performed by two independent observers to detect the endocardial and epicardial borders and subsequently to compute chamber volumes and myocardial mass. Weight of the excised left ventricle was used as a gold standard for myocardial mass. Bland-Altman analysis demonstrated reduced interobserver variability for the measurement of cardiac volumes using the black blood sequence compared to the bright blood sequence (95% confidence interval was -0.89-0.73 mu L for black blood versus -1.86-1.28 mu L for bright blood). Also, Bland-Altman analysis showed that the black blood sequence provides improved accuracy for the measurement of myocardial mass compared to the bright blood sequence (average difference between MRI versus weight was 0.9 mu g for black blood and -11.2 mu g for bright blood, P < 0.01). For myocardial tagging, qualitative assessment demonstrated improved endocardial border definition using the black blood sequence. Black blood cine MRI in mice provides reduced interobserver variability and improved accuracy for the measurement of myocardial volumes and mass compared to the conventional bright blood technique. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:1074 / 1079
页数:6
相关论文
共 25 条
[1]
MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study [J].
Barkhausen, J ;
Ruehm, SG ;
Goyen, M ;
Buck, T ;
Laub, G ;
Debatin, JF .
RADIOLOGY, 2001, 219 (01) :264-269
[2]
COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[3]
Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[4]
Cine MR angiography of the heart with segmented true fast imaging with steady-state precession [J].
Carr, JC ;
Simonetti, O ;
Bundy, J ;
Li, DB ;
Pereles, S ;
Finn, JP .
RADIOLOGY, 2001, 219 (03) :828-834
[5]
MRI/MRS assessment of in vivo murine cardiac metabolism, morphology, and function at physiological heart rates [J].
Chacko, VP ;
Aresta, F ;
Chacko, SM ;
Weiss, RG .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2000, 279 (05) :H2218-H2224
[6]
Precision of myocardial contour estimation from tagged MR images with a "Black-blood" technique [J].
Croisille, P ;
Guttman, MA ;
Atalar, E ;
McVeigh, ER ;
Zerhouni, EA .
ACADEMIC RADIOLOGY, 1998, 5 (02) :93-100
[7]
FAST SELECTIVE BLACK BLOOD MR IMAGING [J].
EDELMAN, RR ;
CHIEN, D ;
KIM, D .
RADIOLOGY, 1991, 181 (03) :655-660
[8]
MR tagging early after myocardial infarction in mice demonstrates contractile dysfunction in adjacent and remote regions [J].
Epstein, FH ;
Yang, ZQ ;
Gilson, WD ;
Berr, SS ;
Kramer, CM ;
French, BA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) :399-403
[9]
Magnetic resonance imaging accurately estimates LV mass in a transgenic mouse model of cardiac hypertrophy [J].
Franco, F ;
Dubois, SK ;
Peshock, RM ;
Shohet, RV .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1998, 274 (02) :H679-H683
[10]
Of mice and men ... and broken hearts [J].
French, BA ;
Yang, ZQ ;
Berr, SS ;
Kramer, CM .
CIRCULATION, 2001, 104 (21) :E110-E110