Comparison of predicted and measured contact pressures in normal and dysplastic hips

被引:82
作者
Michaeli, DA [1 ]
Murphy, SB [1 ]
Hipp, JA [1 ]
机构
[1] HARVARD UNIV, SCH MED, BOSTON, MA 02215 USA
关键词
hip; dysplasia; pressure; geometry;
D O I
10.1016/S1350-4533(96)00051-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Hip dysplasia, a congenital and developmental deformity characterized by malorientation and a reduction of contact area between the femur and acetabulum, is the most common cause of osteoarthritis of the hip. According to current estimates, dysplasia accounts for nearly 76% of all cases of osteoarthritis, and many who are affected require a total hip replacement before the age of 50. It is theorized that in the poorly oriented and deformed pelvis, a reduction in contact area lends to an increase in contact pressure during normal activities. Currently, clinicians attempt to reposition the joint, assuming that improving the position of the existing contact surface will lead to decreased pressures It is also assumed that improving certain geometric parameters correlates indirectly with decreased contact pressures. Neither these simple estimates nor other non-invasive models have ever been shown to be related to contact pressure. The purpose of this study was to evaluate a computerized method of predicting hip joint contact pressures, which applies known hip joint reaction forces to the three-dimensional surface of the hip joint. To this act, cadaveric and plastic pelvic models were developed to test whether the computer model could predict the magnitude and location of maximum pressure. Mechanical testing revealed that the computer model could be used to predict pressure in cadaveric pelves at prescribed locations (r(2)=0.64). The computerized model could also be used to predict the magnitude and location of maximum pressure in a series of plastic models where the lend vector and the degree of dysplasia were parametrically varied (r(2)=0.7). These findings suggest that the computer model may be useful in. identifying patients who will fail osteotomy or whether they can be used to select the best osteotomy for each patient. (C) 1997 Elsevier Science Ltd for IPEM.
引用
收藏
页码:180 / 186
页数:7
相关论文
共 39 条
[1]
QUANTITATIVE-ANALYSIS OF HIP-DYSPLASIA IN CEREBRAL-PALSY - A STUDY OF RADIOGRAPHS AND 3-D REFORMATTED IMAGES [J].
ABEL, MF ;
WENGER, DR ;
MUBARAK, SJ ;
SUTHERLAND, DH .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1994, 14 (03) :283-289
[2]
CONTACT PRESSURES IN THE HUMAN HIP-JOINT [J].
AFOKE, NYP ;
BYERS, PD ;
HUTTON, WC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (04) :536-541
[3]
Aronson J, 1986, Instr Course Lect, V35, P119
[4]
COMPARATIVE-STUDY OF THE INTRINSIC MECHANICAL-PROPERTIES OF THE HUMAN ACETABULAR AND FEMORAL-HEAD CARTILAGE [J].
ATHANASIOU, KA ;
AGARWAL, A ;
DZIDA, FJ .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1994, 12 (03) :340-349
[5]
HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[6]
BOMBELLI R, 1995, J BONE JOINT SURG BR, V77, P141
[7]
A CONTACT-COUPLED FINITE-ELEMENT ANALYSIS OF THE NATURAL ADULT HIP [J].
BROWN, TD ;
DIGIOIA, AM .
JOURNAL OF BIOMECHANICS, 1984, 17 (06) :437-448
[8]
AN ALGORITHM FOR APPROXIMATE CRINKLE ARTIFACT COMPENSATION IN PRESSURE-SENSITIVE FILM RECORDINGS [J].
CALDWELL, NJ ;
HALE, JE ;
RUDERT, MJ ;
BROWN, TD .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :1001-1009
[9]
ROLE OF LOADS AND PROSTHESIS MATERIAL PROPERTIES ON THE MECHANICS OF THE PROXIMAL FEMUR AFTER TOTAL HIP-ARTHROPLASTY [J].
CHEAL, EJ ;
SPECTOR, M ;
HAYES, WC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (03) :405-422
[10]
EARL DE, 1982, THESIS CALIFORNIA ST