Myocardial injury induced by radiofrequency and low energy ablation: A quantitative study of CK isoforms, CK-MB, and troponin-T concentrations

被引:36
作者
Katritsis, DG [1 ]
Hossein-Nia, M [1 ]
Anastasakis, A [1 ]
Poloniecki, J [1 ]
Holt, DW [1 ]
Camm, AJ [1 ]
Ward, DE [1 ]
Rowland, E [1 ]
机构
[1] Univ London St Georges Hosp, Sch Med, Dept Cardiol Sci, London SW17 0RE, England
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1998年 / 21卷 / 07期
关键词
catheter ablation; creatine kinase; troponin-T;
D O I
10.1111/j.1540-8159.1998.tb00212.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We conducted a prospective, controlled study to investigate the use of CK-MB concentration and newer methods such as troponin-T concentration and CK isoforms, in the assessment of myocardial damage caused by radiofrequency current or low energy DC catheter ablation. The study population consisted of 3 consecutive patients who underwent low energy catheter ablation, 28 consecutive patients subjected to radiofrequency ablation, and 4 patients who were subjected to radiofrequency energy ablation but also had external DC shocks for cardioversion of atrial fibrillation that occurred during the procedure. The control group comprised eight subjects undergoing electrophysiological study. Prior to ablation and at 30 minutes, 1, 2, 6, and 12 hours following the procedure, serial blood samples were taken for measurement of troponin-T and CK-MB concentrations, and calculation of the MM3/MM1 and MB2/MB1 ratios. Troponin-T concentration was raised above normal in all patients subjected to low energy ablation and in all but two patients subjected to radiofrequency ablation. Only 42% of all patients subjected to ablation had at least one raised CK-MB concentration postablation. The MB2/MB1 ratio rr.as raised in all but two patients following radiofrequency or low energy ablation but it was also abnormal in the preablation samples in nine patients. The MM3/MM1 ratio failed to detect myocardial damage in 71% of all patients. There was a statistically significant difference between the control and patient groups regarding all four indices of myocardial damage. Low energy ablation caused a significantly higher degree of myocardial damage compared with radiofrequency (RF); this effect could not be attributed to different numbers of total energy discharges. Our results indicate that catheter ablation, regardless of the mode of energy used, inflicts detectable injury upon the myocardium. This injury can be quantitated by using newer analytical techniques, such as serial, postablation measurements of troponin-T concentration.
引用
收藏
页码:1410 / 1416
页数:7
相关论文
共 17 条
  • [1] CREATINE-KINASE ISOFORMS - INVESTIGATION OF INHIBITORS OF INVITRO DEGRADATION AND ESTABLISHMENT OF A REFERENCE RANGE
    DAVIES, J
    REYNOLDS, T
    PENNEY, MD
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 1992, 29 : 202 - 205
  • [2] PREDICTORS OF IN-HOSPITAL MORTALITY AFTER DC CATHETER ABLATION OF ATRIOVENTRICULAR JUNCTION - RESULTS OF A PROSPECTIVE, INTERNATIONAL, MULTICENTER STUDY
    EVANS, GT
    SCHEINMAN, MM
    BARDY, G
    BORGGREFE, M
    BRUGADA, P
    FISHER, J
    FONTAINE, G
    HUANG, SKS
    HUANG, WH
    JOSEPHSON, M
    KUCK, KH
    HLATKY, MA
    LEVY, S
    LISTER, JW
    MARCUS, F
    MORADY, F
    TCHOU, P
    WALDO, AL
    WOOD, D
    [J]. CIRCULATION, 1991, 84 (05) : 1924 - 1937
  • [3] HOSSEINNIA M, 1994, CLIN CHEM, V40, P1265
  • [4] HOSSEINNIA M, 1993, COMMUN LAB MED, V1, P7
  • [5] RADIOFREQUENCY ABLATION OF ACCESSORY PATHWAYS - IMPLICATIONS OF ACCUMULATED EXPERIENCE AND TIME DEDICATED TO PROCEDURES
    KATRITSIS, D
    BASHIR, Y
    HEALD, S
    POLONIECKI, J
    WARD, DE
    [J]. EUROPEAN HEART JOURNAL, 1994, 15 (03) : 339 - 344
  • [6] LOW-ENERGY ABLATION OF ACCESSORY PATHWAYS IN CASES FOR WHICH THE RADIOFREQUENCY APPROACH HAD FAILED
    KATRITSIS, D
    HEALD, S
    BASHIR, Y
    WARD, D
    ROWLAND, E
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (15) : 1211 - 1212
  • [7] KATRITSIS D, HEART DIS, P636
  • [8] KATRITSIS D, IN PRESS EUR HEART J
  • [9] KATUS HA, 1992, CLIN CHEM, V38, P386
  • [10] SERUM CREATINE-KINASE MM ISOENZYME SUB-BANDS AFTER ACUTE MYOCARDIAL-INFARCTION IN MAN
    MORELLI, RL
    CARLSON, CJ
    EMILSON, B
    ABENDSCHEIN, DR
    RAPAPORT, E
    [J]. CIRCULATION, 1983, 67 (06) : 1283 - 1289