Influence of topographical features on the fluoride corrosion of Ni-Ti orthodontic archwires

被引:12
作者
Abalos, C. [2 ]
Paul, A. [3 ]
Mendoza, A. [4 ]
Solano, E. [5 ]
Gil, F. J. [1 ,6 ]
机构
[1] Univ Politecn Cataluna, Dept Ciencia Mat & Ingn Met, E-08028 Barcelona, Spain
[2] Univ Seville, Dept Dent Mat, Sch Dent, Seville, Spain
[3] Univ Seville, Dept Mech & Mat Engn, Sch Engn, Seville, Spain
[4] Univ Seville, Dept Pediat Dent, Sch Dent, Seville, Spain
[5] Univ Seville, Dept Orthodont, Sch Dent, Seville, Spain
[6] Tech Univ Catalonia, Dept Mat Sci & Met Engn, Barcelona, Spain
关键词
ARTIFICIAL SALIVA; SURFACE CHARACTERIZATION; MECHANICAL-PROPERTIES; PROPHYLACTIC AGENTS; SUPERELASTIC ALLOY; IN-VIVO; WIRES; TITANIUM; RESISTANCE; BIOCOMPATIBILITY;
D O I
10.1007/s10856-011-4460-y
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Different manufacturing processes of Ni-Ti archwires respond differently to corrosion due to the surface conditions involved. In this study, several topographical features and their influence upon fluoride corrosion were studied. Four topographies (smooth, dimple, scratch, and crack) according to the main surface defect were characterized (n = 40). Static corrosion tests were performed in artificial saliva with fluorated prophylactic gel (12500 ppm) for 28 days. The surface was characterized by SEM and laser confocal microscopy. Standard electrochemical corrosion (open circuit potential, corrosion potential and corrosion current density) was performed. Statistical analysis was carried out using the ANOVA test (alpha a parts per thousand currency sign 0.05). An increase was observed in the surface defects and/or roughness of the cracked and scratched surfaces. These defects produced an important increase in corrosion behavior. The best surfaces for the orthodontic archwires were the smooth and dimpled surfaces, respectively. The increase in defects was independent of roughness. Manufacturing processes that produce surface cracks should be avoided in orthodontic applications.
引用
收藏
页码:2813 / 2821
页数:9
相关论文
共 35 条
[1]
Surface characterization of retrieved NiTi orthodontic archwires [J].
Eliades, T ;
Eliades, G ;
Athanasiou, AE ;
Bradley, TG .
EUROPEAN JOURNAL OF ORTHODONTICS, 2000, 22 (03) :317-326
[2]
On the properties of two binary NiTi shape memory alloys. Effects of surface finish on the corrosion behaviour and in vitro biocompatibility [J].
Es-Souni, M ;
Es-Souni, M ;
Fischer-Brandies, H .
BIOMATERIALS, 2002, 23 (14) :2887-2894
[3]
ESSOUNI M, 2001, IOK, V33, P87
[4]
Surface analysis of nickel-titanium archwire used in vivo [J].
Grimsdottir, MR ;
Hensten-Pettersen, A .
DENTAL MATERIALS, 1997, 13 (03) :163-167
[5]
Variation in surface topography of different NiTi orthodontic archwires in various commercial fluoride-containing environments [J].
Huang, Her-Hsiung .
DENTAL MATERIALS, 2007, 23 (01) :24-33
[6]
Surface characterizations and corrosion resistance of nickel-titanium orthodontic archwires in artificial saliva of various degrees of acidity [J].
Huang, HH .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2005, 74A (04) :629-639
[7]
Huang HH, 2005, ANGLE ORTHOD, V75, P661
[8]
Ion release from NiTi orthodontic wires in artificial saliva with various acidities [J].
Huang, HH ;
Chiu, YH ;
Lee, TH ;
Wu, SC ;
Yang, HW ;
Su, KH ;
Hsu, CC .
BIOMATERIALS, 2003, 24 (20) :3585-3592
[9]
Hunt NP, 1999, ANGLE ORTHOD, V69, P433
[10]
Kusy RP, 1997, ANGLE ORTHOD, V67, P197