A sensitive amperometric immunosensor for carcinoembryonic antigen detection with porous nanogold film and nano-Au/chitosan composite as immobilization matrix

被引:108
作者
He, Xiulan [1 ]
Yuan, Ruo [1 ]
Chai, Yaqin [1 ]
Shi, Yintao [1 ]
机构
[1] SW Univ, Chongqing Key Lab Analyt Chem, Chongqing 400715, Peoples R China
来源
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS | 2008年 / 70卷 / 06期
基金
中国国家自然科学基金;
关键词
amperometric immunosensor; carcinoembryonic antigen; gold nanoparticle; nano-Au/chitosan composite;
D O I
10.1016/j.jbbm.2007.06.002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive arnperometric immunosensor for carcinoembryonic antigen (CEA) was prepared. Firstly, a porous nano-structure gold (NG) film was formed on glassy carbon electrode (GCE) by electrochemical reduction of HAuCl4 solution, then nano-Au/Chit composite was immobilized onto the electrode because of its excellent membrane-forming ability, and finally the anti-CEA was adsorbed onto the surface of the bilayer gold nanoparticles to construct an anti -CEA/nano-Au/Chit/NG/GCE immunosensor. The characteristics of the modified electrode at different stages of modification were studied by cyclic voltametry (CV). The gold colloid, chitosan and nano-Au/Chit were characterized by transmission electron microscopy and UV-vis spectroscopy. In addition, the performances of the immunosensor were studied in detail. The resulting immunosensor offers a high-sensitivity (13 10 nA/ng/ml) for the detection of CEA and has good correlation for detection of CEA in the range of 0.2 to 120.0 ng/ rnl with a detection limit of 0.06 ng/ml estimated at a signal-to-noise ratio of 3. The proposed method can detect the CEA through one-step immunoassay and would be valuable for clinical immunoassay. (c) 2007 Published by Elsevier B. V.
引用
收藏
页码:823 / 829
页数:7
相关论文
共 29 条
[1]  
[Anonymous], LUNG CANC
[2]   Realization and characterization of porous gold for increased protein coverage on acoustic sensors [J].
Bonroy, K ;
Friedt, JM ;
Frederix, F ;
Laureyn, W ;
Langerock, S ;
Campitelli, A ;
Sára, M ;
Borghs, G ;
Goddeeris, B ;
Declerck, P .
ANALYTICAL CHEMISTRY, 2004, 76 (15) :4299-4306
[3]  
Bremer K., 1995, EUR J CANCER, V31, pS262
[4]   Serum tumor markers in metastatic breast cancer comparative study between CEA, CA-15.3 and MCA [J].
Carneiro, C ;
Costa, L ;
Melo, M ;
Quintela, A ;
Miranda, I ;
Jorge, M ;
Pina, F ;
Gouveia, A ;
Miguel, MJ ;
Costa, EB .
EUROPEAN JOURNAL OF CANCER, 1998, 34 :S43-S43
[5]  
Carralero V., 2005, ANAL CHIM ACTA, V528, P1
[6]   Impedance immunosensor based on receptor protein adsorbed directly on porous gold film [J].
Chen, ZP ;
Jiang, JH ;
Shen, GL ;
Yu, RQ .
ANALYTICA CHIMICA ACTA, 2005, 553 (1-2) :190-195
[7]   Serum anti-p53 antibodies in lung cancer: comparison with established tumor markers [J].
Cioffi, M ;
Vietri, MT ;
Gazzerro, P ;
Magnetta, R ;
D'Auria, A ;
Durante, A ;
Nola, E ;
Puca, GA ;
Molinari, AM .
LUNG CANCER, 2001, 33 (2-3) :163-169
[8]   Electrochemical sensor for immunoassay of carcinoembryonic antigen based on thionine monolayer modified gold electrode [J].
Dai, Z ;
Chen, J ;
Yan, F ;
Ju, HX .
CANCER DETECTION AND PREVENTION, 2005, 29 (03) :233-240
[9]   Novel amperometric immunosensor for rapid separation-free immunoassay of carcinoembryonic antigen [J].
Dai, Z ;
Yan, F ;
Hua, Y ;
Hu, XY ;
Ju, HX .
JOURNAL OF IMMUNOLOGICAL METHODS, 2004, 287 (1-2) :13-20
[10]   Carcinoembryonic antigen (CEA) presentation and specific T cell-priming by human dendritic cells transfected with CEA-mRNA [J].
Eppler, E ;
Hörig, H ;
Kaufman, HL ;
Groscurth, P ;
Filgueira, L .
EUROPEAN JOURNAL OF CANCER, 2002, 38 (01) :184-193