Cross-calibration, precision and patient dose measurements in preparation for clinical trials using dual energy X-ray absorptiometry of the lumbar spine

被引:22
作者
Cawte, SA
Pearson, D
Green, DJ
Maslanka, WB
Miller, CG
Rogers, AT
机构
[1] City Hosp Nottingham, NHS Trust, Dept Radiol, Nottingham, England
[2] City Hosp Nottingham, NHS Trust, Dept Phys Med, Nottingham, England
[3] Bona Fide Ltd, Madison, WI USA
关键词
D O I
10.1259/bjr.72.856.10474496
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Large, multicentre clinical trials using DXA to monitor bone density following intervention are now common. At the same time, several different bone densitometers and calibration phantoms are currently in use. The aim of this study was to document the technical information required on cross-calibration of equipment, reproducibility and patient dose before commencing a multicentre clinical trial. To this end, we obtained an in vitro and in vivo cross-calibration of two machines (a Hologic QDR 2000 and a Lunar DPX-L) that were not significantly different. Interobserver and intraobserver precision, and radiation dose were also measured and three commonly used phantoms assessed for their usefulness in cross-calibration and quality assurance. Measured in vitro precision on the two machines (0.3-0.7%) was better than that specified by the manufacturers. In vivo precision was worse (1.4-2.1%), as might be expected in patients with reduced bone mass. Mean entrance skin radiation doses on each machine were 280 mu Sv for the QDR 2000 and 38 mu SV for the DPX-L. No one phantom is ideal, but the European Spine Phantom or Lunar Aluminium Spine Phantom will provide an adequate cross-calibration for a clinical trial. This study demonstrates that an adequate cross-calibration can be obtained for use in groups of patients and that the equipment used is reproducible with a low radiation output.
引用
收藏
页码:354 / 362
页数:9
相关论文
共 21 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
DEVOGELAER JP, 1993, CALCIFIED TISSUE INT, V52, P164
[3]  
FELDMANN U, 1981, J CLIN CHEM CLIN BIO, V19, P121
[4]  
GENANT HK, 1994, J BONE MINER RES, V9, P1503
[5]   QUALITY ASSURANCE FOR BONE DENSITOMETRY RESEARCH STUDIES - CONCEPT AND IMPACT [J].
GLUER, CC ;
FAULKNER, KG ;
ESTILO, MJ ;
ENGELKE, K ;
ROSIN, J ;
GENANT, HK .
OSTEOPOROSIS INTERNATIONAL, 1993, 3 (05) :227-235
[6]   DUAL-ENERGY RADIOGRAPHIC ABSORPTIOMETRY OF THE LUMBAR SPINE - CLINICAL-EXPERIENCE WITH 2 DIFFERENT SYSTEMS [J].
GUNDRY, CR ;
MILLER, CW ;
RAMOS, E ;
MOSCONA, A ;
STEIN, JA ;
MAZESS, RB ;
SARTORIS, DJ ;
RESNICK, D .
RADIOLOGY, 1990, 174 (02) :539-541
[8]   EFFECTIVE DOSE VALUES IN BONE-MINERAL MEASUREMENTS BY PHOTON-ABSORPTIOMETRY AND COMPUTED-TOMOGRAPHY [J].
KALENDER, WA .
OSTEOPOROSIS INTERNATIONAL, 1992, 2 (02) :82-87
[9]  
Kanis J A, 1991, Osteoporos Int, V1, P182, DOI 10.1007/BF01625451
[10]   COMPARATIVE PERFORMANCE INVITRO AND INVIVO OF LUNAR DPX AND HOLOGIC QDR-1000 DUAL ENERGY X-RAY ABSORPTIOMETERS [J].
LASKEY, MA ;
FLAXMAN, ME ;
BARBER, RW ;
TRAFFORD, S ;
HAYBALL, MP ;
LYTTLE, KD ;
CRISP, AJ ;
COMPSTON, JE .
BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (767) :1023-1029