Construct validity of myotonometric measurements of muscle compliance as a measure of strength

被引:29
作者
Gubler-Hanna, Coral
Laskin, James
Marx, Benjamin J.
Leonard, Charles T. [1 ]
机构
[1] Univ Montana, Coll Hlth & Biomed Sci, Motor Control Res Lab, Sch Phys Therapy & Rehabil Sci, Missoula, MT 59812 USA
[2] Neuron Technol Inc, Missoula, MT 59812 USA
关键词
muscle compliance; myotonometer; electromyography; isometric; strength testing;
D O I
10.1088/0967-3334/28/8/013
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Myotonometric measurement of muscle compliance represents new technology that quantifies muscle tone. Compliance change during muscle contraction might provide an indirect measure of strength. The purpose of this study was to determine relationships among myotonometric measurements of muscle compliance, surface electromyographic ( sEMG) measurements of muscle activation and joint force production during voluntary isometric knee extensions. The level of relationship will contribute to the construct validity of use of muscle compliance as an indirect strength measurement. Thirteen male subjects, mean age 25 +/- 1.5 years, participated. Simultaneous recordings of myotonometric, sEMG of the rectus femoris and isometric knee extension force measurements were taken at rest, during maximal voluntary contraction ( MVC), and during 33% and 66% MVC contractions. Relationships among the three measurement procedures were calculated using correlation and regression analyses. Myotonometric measures of muscle compliance, sEMG and force measurements were highly correlated. Myotonometric measurements were best represented by a curvilinear ( quadratic) relationship to sEMG ( r = 0.82, p < 0.001) and joint force ( r = 0.83, p < 0.001). The present experiments establish the construct validity of myotonometric measurements of muscle compliance as an indirect means of quantifying muscle strength and activation levels. This method, therefore, offers a possible alternative for cases in which direct measurement of joint force or sEMG is difficult or inappropriate.
引用
收藏
页码:913 / 924
页数:12
相关论文
共 25 条
[1]   Feasibility of the use of a novel soft tissue stiffness meter [J].
Arokoski, JPA ;
Surakka, J ;
Ojala, T ;
Kolari, P ;
Jurvelin, JS .
PHYSIOLOGICAL MEASUREMENT, 2005, 26 (03) :215-228
[2]   Reliability of a new, hand-held device for assessing skeletal muscle stiffness [J].
Bizzini, M ;
Mannion, AF .
CLINICAL BIOMECHANICS, 2003, 18 (05) :459-461
[3]   THE MECHANICAL-BEHAVIOR OF ACTIVE HUMAN SKELETAL-MUSCLE IN SMALL OSCILLATIONS [J].
CANNON, SC ;
ZAHALAK, GI .
JOURNAL OF BIOMECHANICS, 1982, 15 (02) :111-121
[4]  
CHATTANOOGA, 1995, KINCOM REFERENCE MAN
[5]  
CRAM JR, 1998, ANATOMY PHYSL INTRO
[6]   The utility of isokinetic dynamometry in the assessment of human muscle function [J].
Gleeson, NP ;
Mercer, TH .
SPORTS MEDICINE, 1996, 21 (01) :18-34
[7]  
GUBLER HC, 2005, J ORTHOP SPORT PHYS, V35, P85
[8]   Biomechanical changes elicited by an anterior cruciate ligament deficiency during steady rate cycling [J].
Hunt, MA ;
Sanderson, DJ ;
Moffet, H ;
Inglis, JT .
CLINICAL BIOMECHANICS, 2003, 18 (05) :393-400
[9]   ISOTONIC LENGTHENING AND SHORTENING MOVEMENTS OF CAT SOLEUS MUSCLE [J].
JOYCE, GC ;
RACK, PMH .
JOURNAL OF PHYSIOLOGY-LONDON, 1969, 204 (02) :475-&
[10]   RELIABILITY AND VALIDITY OF A DEVICE TO MEASURE MUSCLE HARDNESS [J].
Kato, Gohei ;
Andrew, Paul D. ;
Sato, Haruhiko .
JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2004, 4 (02) :213-225