Monitoring the temperature of dilute aqueous solutions using near-infrared water absorption

被引:29
作者
Otal, EH [1 ]
Inóñ, FA [1 ]
Andrade, FJ [1 ]
机构
[1] Univ Buenos Aires, Fac Ciencias Exactas & Nat, Dept Quim Inorgan Analit & Quim Fis, INQUIMAE,Lab Anal Trazas, Buenos Aires, DF, Argentina
关键词
spectroscopic temperature measurement; near infrared; NIR;
D O I
10.1366/000370203322005355
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An alternative spectroscopic approach for monitoring the temperature of aqueous solutions is presented. The method is based upon the temperature-induced spectral changes undergone by the second overtone (around 960 nm) of the near-infrared (NIR) water absorption band. Single and multilinear regression analysis are tested in order to evaluate the predictive ability of temperature. A linear dependence is found when measurements are performed at a single wavelength, but a lower prediction error is obtained when multilinear models are applied. No matrix effects produced by moderately concentrated common dissolved ions are found in a broad range of pH. A signal-to-noise ratio allows a precision of 0.5 degreesC for temperature monitoring. A prediction error of 0.77 degreesC (single linear regression) and 0.25 degreesC (multilinear approach) are achieved in a range from 15 to 90 degreesC. Advantages in terms of instrumentation and data analysis required are discussed.
引用
收藏
页码:661 / 666
页数:6
相关论文
共 20 条
[1]   Spectroscopic measurements of temperature with uranyl compounds [J].
Barabas, L ;
Gorguinpour, C ;
Leung, AF ;
McCoy, J .
APPLIED SPECTROSCOPY, 2001, 55 (10) :1382-1384
[2]   NTR calibration in non-linear systems:: different PLS approaches and artificial neural networks [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
Pagès, J .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2000, 50 (01) :75-82
[3]   A LASER TEMPERATURE-JUMP APPARATUS BASED ON COMMERCIAL PARTS EQUIPPED WITH HIGHLY SENSITIVE SPECTROPHOTOMETRIC DETECTION [J].
BREMER, C ;
BERGBAUER, R ;
RUF, H ;
BANNISTER, JJ ;
GRELL, E .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1993, 4 (12) :1385-1393
[4]   A dual fluorescence temperature sensor based on perylene/exciplex interconversion [J].
Chandrasekharan, N ;
Kelly, LA .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (40) :9898-9899
[5]   A fluorescent temperature probe based on the association between the excited states of 4-(N,N-dimethylamino)benzonitrile and β-cyclodextrin [J].
Figueroa, ID ;
El Baraka, M ;
Quiñones, E ;
Rosario, O .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3974-3977
[6]  
Kawano S., 1995, J NEAR INFRARED SPEC, V3, P211, DOI DOI 10.1255/JNIRS.71
[7]  
Lewi P. J., 1997, HDB CHEMOMETRICS Q B
[8]   NEAR-IR SPECTROSCOPIC DETERMINATION OF NACL IN AQUEOUS-SOLUTION [J].
LIN, J ;
BROWN, CW .
APPLIED SPECTROSCOPY, 1992, 46 (12) :1809-1815
[9]   Near-IR calibration transfer between different temperatures [J].
Lin, J .
APPLIED SPECTROSCOPY, 1998, 52 (12) :1591-1596
[10]   UNIVERSAL APPROACH FOR DETERMINATION OF PHYSICAL AND CHEMICAL-PROPERTIES OF WATER BY NEAR-IR SPECTROSCOPY [J].
LIN, J ;
BROWN, CW .
APPLIED SPECTROSCOPY, 1993, 47 (10) :1720-1727