Improved centric phase encoding orders for three-dimensional magnetization-prepared MR angiography

被引:57
作者
Wilman, AH [1 ]
Riederer, SJ [1 ]
机构
[1] MAYO CLIN & MAYO FDN, MR RES LAB, ROCHESTER, MN 55905 USA
关键词
centric phase encode order; MR angiography; magnetization preparation;
D O I
10.1002/mrm.1910360309
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
New centric phase encoding orders are introduced for transient state three-dimensional MR imaging. Unlike previous centric orders, these variants are not fixed with respect to differences in the relative y and z fields of view, but are tailored to account for the differential degrees of gradient dephasing in the k(y) and k(z) phase encoding directions and thus maintain the highest weighting for the most central k-space values. The new centric orders are compared with previous methods in both simulation and experimental magnetization-prepared MR angiography of the carotid and renal arteries. In comparison with other tested centric orders, the new methods provided better retention of true vessel shape caused by isotropic blurring across the phase encoding plane. In addition, the new methods provided increased contrast, with the degree of improvement over previous methods depending on vessel orientation, size, and degree of inflow.
引用
收藏
页码:384 / 392
页数:9
相关论文
共 22 条
[1]   CENTRIC PHASE-ENCODING ORDER IN 3-DIMENSIONAL MP-RAGE SEQUENCES - APPLICATION TO ABDOMINAL IMAGING [J].
BAMPTON, AEH ;
RIEDERER, SJ ;
KORIN, HW .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03) :327-334
[2]   FAST TIME-OF-FLIGHT MR-ANGIOGRAPHY WITH IMPROVED BACKGROUND SUPPRESSION [J].
EDELMAN, RR ;
CHIEN, D ;
ATKINSON, DJ ;
SANDSTROM, J .
RADIOLOGY, 1991, 179 (03) :867-870
[3]   MR VASCULAR IMAGING WITH A FAST GRADIENT REFOCUSING PULSE SEQUENCE AND REFORMATTED IMAGES FROM TRANSAXIAL SECTIONS [J].
GULLBERG, GT ;
WEHRLI, FW ;
SHIMAKAWA, A ;
SIMONS, MA .
RADIOLOGY, 1987, 165 (01) :241-246
[4]   SNAPSHOT FLASH MRI - APPLICATIONS TO T1, T2, AND CHEMICAL-SHIFT IMAGING [J].
HAASE, A .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (01) :77-89
[5]   FAST 3-DIMENSIONAL IMAGING OF CEREBROSPINAL-FLUID [J].
HENNIG, J ;
FRIEDBURG, H ;
OTT, D .
MAGNETIC RESONANCE IN MEDICINE, 1987, 5 (04) :380-383
[6]   THE IMPORTANCE OF PHASE-ENCODING ORDER IN ULTRA-SHORT TR SNAPSHOT MR IMAGING [J].
HOLSINGER, AE ;
RIEDERER, SJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (03) :481-488
[7]   MR ANGIOGRAPHY WITH TWO-DIMENSIONAL ACQUISITION AND 3-DIMENSIONAL DISPLAY - WORK IN PROGRESS [J].
KELLER, PJ ;
DRAYER, BP ;
FRAM, EK ;
WILLIAMS, KD ;
DUMOULIN, CL ;
SOUZA, SP .
RADIOLOGY, 1989, 173 (02) :527-532
[8]   ALTERED PHASE-ENCODING ORDER FOR REDUCED SENSITIVITY TO MOTION IN 3-DIMENSIONAL MR IMAGING [J].
KORIN, HW ;
RIEDERER, SJ ;
BAMPTON, AEH ;
EHMAN, RL .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (06) :687-693
[9]   CORONARY-ARTERIES - 3-DIMENSIONAL MR-IMAGING WITH FAT SATURATION AND MAGNETIZATION TRANSFER CONTRAST [J].
LI, D ;
PASCHAL, CB ;
HAACKE, EM ;
ADLER, LP .
RADIOLOGY, 1993, 187 (02) :401-406
[10]   3-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY USING SELECTIVE INVERSION-RECOVERY RAGE WITH FAT-SATURATION AND ECG-TRIGGERING - APPLICATION TO RENAL-ARTERIES [J].
LI, D ;
HAACKE, EM ;
MUGLER, JP ;
BERR, S ;
BROOKEMAN, JR ;
HUTTON, MC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (04) :414-422