Control techniques for active power filters

被引:146
作者
Green, TC [1 ]
Marks, JH [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Elect Engn, London SW7 2AZ, England
来源
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS | 2005年 / 152卷 / 02期
关键词
D O I
10.1049/ip-epa:20040759
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 [电气工程]; 0809 [电子科学与技术];
摘要
There have been many variants of the active power filter proposed and these variations cover both the circuit topology and the control system employed. Some of the control variants reflect different control objectives but there are still many variants within similar objectives. The available control techniques are described and contrasted in a structured way to identify their performance strengths. Objectives are classified by the supply current components to be corrected and by the response required to distorted grid voltage. The various signal transformations are described in terms of their impact on the distortion identification problem. Time-domain, frequency-domain, instantaneous power and impedance synthesis methods are examined. Additional control functions such as DC-bus voltage and current reference following are also discussed. It is found that a key difference between control methods is the way in which current distortion is treated in the presence of distorted grid voltage.
引用
收藏
页码:369 / 381
页数:13
相关论文
共 81 条
[1]
AKAGI H, 1993, EUR T ELECTR POW, V3, P27
[2]
New trends in active filters for power conditioning [J].
Akagi, H .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1996, 32 (06) :1312-1322
[3]
CONTROL STRATEGY OF ACTIVE POWER FILTERS USING MULTIPLE VOLTAGE-SOURCE PWM CONVERTERS [J].
AKAGI, H ;
NABAE, A ;
ATOH, S .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1986, 22 (03) :460-465
[4]
Control strategy and site selection of a shunt active filter for damping of harmonic propagation in power distribution systems [J].
Akagi, H .
IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (01) :354-363
[5]
INSTANTANEOUS REACTIVE POWER COMPENSATORS COMPRISING SWITCHING DEVICES WITHOUT ENERGY-STORAGE COMPONENTS [J].
AKAGI, H ;
KANAZAWA, Y ;
NABAE, A .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1984, 20 (03) :625-630
[6]
Allmeling JH, 2002, IEEE POWER ELECTRON, P376, DOI 10.1109/PSEC.2002.1023897
[7]
HARMONIC REDUCTION IN THYRISTOR CONVERTERS BY HARMONIC CURRENT INJECTION [J].
AMETANI, A .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1976, 95 (02) :441-449
[8]
NEW CONTROL ALGORITHMS FOR SERIES AND SHUNT 3-PHASE 4-WIRE ACTIVE POWER FILTERS [J].
AREDES, M ;
WATANABE, EH .
IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (03) :1649-1656
[9]
Bhattacharya S, 1995, IEEE IND APPLIC SOC, P2531, DOI 10.1109/IAS.1995.530625
[10]
BHATTACHARYA S, 1991, P EPE C FLOR IT, P30