Range of motion of large head total hip arthroplasty is greater than 28 mm total hip arthroplasty or hip resurfacing

被引:31
作者
Lavigne, Martin [1 ,2 ]
Ganapathi, Muthu [3 ]
Mottard, Sophie [1 ]
Girard, Julien [1 ]
Vendittoli, Pascal-Andre [2 ]
机构
[1] Hop Maison Neuve Rosemont, Montreal, PQ H1T 4B3, Canada
[2] Univ Montreal, Dept Surg, Quebec City, PQ, Canada
[3] Ysbyty Gwynedd, Dept Orthopaed, Bangor, Gwynedd, Wales
关键词
Range of motion; Large diameter head total hip arthropalsty; Hip resurfacing; Function; IN-VITRO; KNEE; IMPINGEMENT; REPLACEMENT; FLEXION; JOINT; SIZE; DISABILITY; COMPONENTS;
D O I
10.1016/j.clinbiomech.2010.11.001
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Background: Reduced range of motion of the hip has a detrimental influence on lower limb function. Large diameter head total hip arthroplasty may theoretically have a greater potential for restoring normal hip range of motion due to greater head-neck diameter ratio, and hence provide better function compared to conventional or hip resurfacing arthroplasty. Method: At minimum one year follow-up, range of motion of the operated and contra lateral hips was clinically assessed using digital photographs and bony landmarks in a clinical comparative study. We assessed if 1) large diameter head total hip arthroplasty (55 patients) restores better hip range of motion compared to 28 mm total hip arthroplasty (50 patients) or hip resurfacing (60 patients) 2) large diameter head total hip arthroplasty achieves same hip range of motion as contra lateral normal hips and 3) hip range of motion correlates with the WOMAC score. Findings: The large diameter head total hip arthroplasty group had significantly greater total arcs of motion (approximately 20), mostly due to an increase of hip flexion and external rotation, but did not reach normal hip motion. The hip range of motion showed significant correlation with the WOMAC score, especially the flexion arc. Interpretation: The better hip range of motion of large diameter head total hip arthroplasty is likely due to the greater head to neck diameter ratio and hence seems to be the best option to optimize range of hip motion and improve function after hip arthroplasty. (c) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:267 / 273
页数:7
相关论文
共 38 条
[1]
AMSTUTZ HC, 1975, CLIN ORTHOP RELAT R, P124
[2]
BELLAMY N, 1988, J RHEUMATOL, V15, P1833
[3]
Less range of motion with resurfacing arthroplasty than with total hip arthroplasty In vitro examination of 8 designs [J].
Bengs, Benjamin C. ;
Sangiorgio, Sophia N. ;
Ebramzadeh, Edward .
ACTA ORTHOPAEDICA, 2008, 79 (06) :755-762
[4]
A STATISTICAL-ANALYSIS OF HIP SCORES [J].
BRYANT, MJ ;
KERNOHAN, WG ;
NIXON, JR ;
MOLLAN, RAB .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (05) :705-709
[5]
Range of motion and stability in total hip arthroplasty with 28-, 32-, 38-, and 44-mm femoral head sizes - An in vitro study [J].
Burroughs, BR ;
Hallstrom, B ;
Golladay, GJ ;
Hoeffel, D ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 2005, 20 (01) :11-19
[6]
CHANDLER DR, 1982, CLIN ORTHOP RELAT R, P284
[7]
CLARKE IC, 1982, ORTHOP CLIN N AM, V13, P681
[8]
The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios [J].
D'Lima, DD ;
Urquhart, AG ;
Buehler, KO ;
Walker, RH ;
Colwell, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) :315-321
[9]
The importance of range of motion after total hip arthroplasty [J].
Davis, Kenneth E. ;
Ritter, Merrill A. ;
Berend, Michael E. ;
Meding, John B. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (465) :180-184
[10]
Range of motion after total hip resurfacing [J].
dela Rosa, Mylene A. ;
Silva, Mauricio ;
Heisel, Christian ;
Reich, Michael ;
Schmalzried, Thomas P. .
ORTHOPEDICS, 2007, 30 (05) :352-357