Determination of hexavalent chromium in lime-treated sewage sludge by anion-exchange fast protein liquid chromatography with electrothermal atomic absorption spectrometry detection

被引:28
作者
Milacic, R [1 ]
Scancar, J [1 ]
机构
[1] Jozef Stefan Inst, Dept Environm Sci, Ljubljana 1000, Slovenia
关键词
D O I
10.1039/b006533l
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The applicability of an anion-exchange fast protein liquid chromatographic-electrothermal atomic absorption spectrometric procedure (FPLC-ETAAS) was investigated for the determination of trace amounts of Cr(vi) in lime-treated sewage sludge. Samples of sewage sludge and sludge mixed with sawdust (volume ratio 1 + 1) with a pH of 8.0 and 7.8, respectively, as well as their mixtures with 5% of quicklime with a pH of 12 were analysed. Liming was applied for sludge stabilisation and disinfection. TRIS-HCl buffer (0.005 mol dm(-3), pH 8.0) and the same buffer with NaCl (0.5 mol dm(-3)) were employed in gradient elution (15 min, flow rate 1 cm(3) min(-1)). The separated Cr species were determined 'off line' by ETAAS in 0.5 cm(3) fractions. It was experimentally proven that Cr(vi) was reproducibly and quantitatively eluted from 12.0 to 13.0 min with a maximum peak at 12.5 min. The repeatability of measurement for a standard solution of 25.0 ng cm(-3) of Cr(vi) was found to be 4.0% and the LOD 1.5 ng cm(-3) of Cr(vi). The technique was successfully applied for the determination of Cr(vi) in lime-treated sewage sludge. In aqueous extracts of untreated sewage sludge Cr(vi) was not detected. In aqueous extracts of lime-treated sewage sludge Cr(vi) was determined 48 h after liming [the concentration was about 200 ng g(-1) Cr(vi)] and was monitored over a time span of six months. The validation of the procedure was performed by analysis of a certified reference material, spiking of samples (recoveries from 93 to 101%) and comparative analysis of Cr(vi) in the fraction eluted at 12.5 min by the ion chromatography thermal lens spectrometry technique. The applied FPLC-ETAAS procedure was found to be a reliable and sensitive technique for the determination of traces of Cr(vi) in lime-treated sewage sludge and investigation of oxidation-reduction processes of Cr. The LOD for sludge samples analysed was 20 ng g(-1) of Cr(vi) and the repeatability of measurement 6.5%.
引用
收藏
页码:1938 / 1942
页数:5
相关论文
共 28 条
[1]   CHROMIUM CYCLING IN SOILS AND WATER - LINKS, GAPS, AND METHODS [J].
BARTLETT, RJ .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1991, 92 :17-24
[2]   Simultaneous chromium(VI) reduction and phenol degradation in an anaerobic consortium of bacteria [J].
Chirwa, EN ;
Wang, YT .
WATER RESEARCH, 2000, 34 (08) :2376-2384
[3]   Optimization of the simultaneous determination of Cr(VI) and Cr(VI) by ion chromatography with chemiluminescence detection [J].
Derbyshire, M ;
Lamberty, A ;
Gardiner, PHE .
ANALYTICAL CHEMISTRY, 1999, 71 (19) :4203-4207
[4]   KINETICS OF CHROMIUM(III) OXIDATION TO CHROMIUM(VI) BY REACTION WITH MANGANESE-DIOXIDE [J].
EARY, LE ;
RAI, D .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1987, 21 (12) :1187-1193
[5]   Determination and correction of analytical biases and study on chemical mechanisms in the analysis of Cr(VI) in soil samples using EPA protocols [J].
Huo, DW ;
Lu, YS ;
Kingston, HM .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1998, 32 (21) :3418-3423
[6]  
KATZ SA, 1994, BIOL ENV CHEM CHROMI, P2
[7]  
KRUZ FG, 1995, J ENV SCI HLTH A, V30, P299
[8]  
Kumar SJ, 1999, ATOM SPECTROSC, V20, P194
[9]   Quantification of total chromium and hexavalent chromium in UHT milk by ETAAS [J].
Lameiras, J ;
Soares, ME ;
Bastos, ML ;
Ferreira, M .
ANALYST, 1998, 123 (10) :2091-2095
[10]   Sequential injection wetting film extraction applied to the spectrophotometric determination of chromium(VI) and chromium(III) in water [J].
Luo, YY ;
Nakano, S ;
Holman, DA ;
Ruzicka, J ;
Christian, GD .
TALANTA, 1997, 44 (09) :1563-1571