Qualitative and quantitative ultrashort echo time (UTE) imaging of cortical bone

被引:212
作者
Du, Jiang [1 ]
Carl, Michael [2 ]
Bydder, Mark [1 ]
Takahashi, Atsushi [2 ]
Chung, Christine B. [1 ]
Bydder, Graeme M. [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[2] GE Healthcare, Global Appl Sci Lab, Menlo Pk, CA 94025 USA
关键词
Ultrashort TE; Projection reconstruction; Adiabatic inversion; Bone water concentration; Relaxation times; NUCLEAR-MAGNETIC-RESONANCE; PROTON PROJECTION MRI; LONG-T-2; SUPPRESSION; RF EXCITATION; WATER; PULSES; CONTRAST; RELAXATION; SEQUENCES; DENSITY;
D O I
10.1016/j.jmr.2010.09.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe the use of two-dimensional ultrashort echo time (2D UTE) sequences with minimum TEs of 8 mu s to image and quantify cortical bone on a clinical 3T scanner. An adiabatic inversion pulse was used for long T(2) water and fat signal suppression. Adiabatic inversion prepared UTE acquisitions with varying TEs were used for T(2) measurement. Saturation recovery UTE acquisitions were used for T(1) measurement. Bone water concentration was measured with the aid of an external reference phantom. UTE techniques were evaluated on cadaveric specimens and healthy volunteers. A signal-to-noise ratio of around 30, contrast-to-noise ratio of around 27/20 between bone and muscle/fat were achieved in tibia in vivo with a nominal voxel size of 0.23 x 0.23 x 6.0 mm(3) in a scan time of 5 min. A mean T1 of 223 +/- 11 ms and mean T(2) of 390 +/- 19 mu s were found. Mean bone water concentrations of 23.3 +/- 1.6% with UTE and 21.7 +/- 1.3% with adiabatic inversion prepared UTE sequences were found in tibia in five normal volunteers. The results show that in vivo qualitative and quantitative evaluation of cortical bone is feasible with 2D UTE sequences. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:304 / 311
页数:8
相关论文
共 32 条
[1]   LUNG PARENCHYMA - PROJECTION RECONSTRUCTION MR-IMAGING [J].
BERGIN, CJ ;
PAULY, JM ;
MACOVSKI, A .
RADIOLOGY, 1991, 179 (03) :777-781
[2]   Quantitative Bone Matrix Density Measurement by Water- and Fat-Suppressed Proton Projection MRI (WASPI) With Polymer Calibration Phantoms [J].
Cao, Haihui ;
Ackerman, Jerome L. ;
Hrovat, Mirko I. ;
Graham, Lila ;
Glimcher, Melvin J. ;
Wu, Yaotang .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) :1433-1443
[3]   Optimization of RF Excitation to Maximize Signal and T2 Contrast of Tissues With Rapid Transverse Relaxation [J].
Carl, Michael ;
Bydder, Mark ;
Du, Jiang ;
Takahashi, Atsushi ;
Han, Eric .
MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (02) :481-490
[4]   VARIABLE-RATE SELECTIVE EXCITATION [J].
CONOLLY, S ;
NISHIMURA, D ;
MACOVSKI, A ;
GLOVER, G .
JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (03) :440-458
[5]   Bone poroelasticity [J].
Cowin, SC .
JOURNAL OF BIOMECHANICS, 1999, 32 (03) :217-238
[6]  
DU J, 2007, P ISMRM 15 ANN M BER, pP381
[7]   Two-dimensional ultrashort echo time imaging using a spiral trajectory [J].
Du, Jiang ;
Bydder, Mark ;
Takahashi, Atsushi M. ;
Chung, Christine B. .
MAGNETIC RESONANCE IMAGING, 2008, 26 (03) :304-312
[8]   Ultrashort echo time spectroscopic imaging (UTESI) of cortical bone [J].
Du, Jiang ;
Hamilton, Gavin ;
Takahashi, Atsushi ;
Bydder, Mark ;
Chung, Christine B. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (05) :1001-1009
[9]   Dual Inversion Recovery, Ultrashort Echo Time (DIR UTE) Imaging: Creating High Contrast for Short-T2 Species [J].
Du, Jiang ;
Takahashi, Atsushi M. ;
Bae, Won C. ;
Chung, Christine B. ;
Bydder, Graeme M. .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (02) :447-455
[10]   Ultrashort TE Imaging With Off-Resonance Saturation Contrast (UTE-OSC) [J].
Du, Jiang ;
Takahashi, Atsushi M. ;
Bydder, Mark ;
Chung, Christine B. ;
Bydder, Graeme M. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (02) :527-531