Ultrashort echo time spectroscopic imaging (UTESI) of cortical bone

被引:72
作者
Du, Jiang
Hamilton, Gavin
Takahashi, Atsushi
Bydder, Mark
Chung, Christine B.
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[2] GE Healthcare, Global Appl Sci Lab, Menlo Pk, CA USA
关键词
ultrashort TE; projection reconstruction; magnetic resonance spectroscopy; bone imaging; short T-2* species;
D O I
10.1002/mrm.21397
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cortical bone in the mature skeleton has a short T-2(*) and produces no detectable signal with conventional MR sequences. A two-dimensional ultrashort echo time (LITE) sequence employing half radio frequency (RF) pulse excitations and radial ramp sampling reduces the effective TE to 8 mu s and is capable of detecting signals from cortical bone. We propose a time-efficient LITE spectroscopic imaging (UTESI) technique based on an interleaved variable TE acquisition, preceded by long T-2(*) signal suppression using either a 90 degrees pulse and gradient dephasing or an inversion pulse and nulling. The projections were divided into multiple groups with the data for each group being collected with progressively increasing TE and interleaved projection angles. The undersampled projections within each group sparsely covered k-space. A view sharing and sliding window reconstruction algorithm was implemented to reconstruct images at each TE, followed by Fourier transformation in the time domain to generate spectroscopic images T-2(*) was quantified through either exponential fitting of the time domain images or line fitting of the magnitude spectrum. Relative water content and the resonance frequency shift due to bulk susceptibility were also evaluated. The feasibility of this technique was demonstrated with phantom and volunteer studies on a clinical 3T scanner.
引用
收藏
页码:1001 / 1009
页数:9
相关论文
共 43 条
[1]   Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory [J].
Barger, AV ;
Block, WF ;
Toropov, Y ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) :297-305
[2]  
Bothakur A, 1998, P 6 ANN M ISMRM SYDN
[3]  
BRITTAIN JH, 2004, P 12 ANN M ISMRM KYO
[4]   NMR CHEMICAL-SHIFT IMAGING IN 3 DIMENSIONS [J].
BROWN, TR ;
KINCAID, BM ;
UGURBIL, K .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1982, 79 (11) :3523-3526
[5]   Detection of hydroxyl ions in bone mineral by solid-state NMR spectroscopy [J].
Cho, GY ;
Wu, YT ;
Ackerman, JL .
SCIENCE, 2003, 300 (5622) :1123-1127
[6]   VARIABLE-RATE SELECTIVE EXCITATION [J].
CONOLLY, S ;
NISHIMURA, D ;
MACOVSKI, A ;
GLOVER, G .
JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (03) :440-458
[7]   QUALITY - QUANTIFICATION IMPROVEMENT BY CONVERTING LINESHAPES TO THE LORENTZIAN TYPE [J].
DEGRAAF, AA ;
VANDIJK, JE ;
BOVEE, WMMJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (03) :343-357
[8]   Time-resolved, undersampled projection reconstruction imaging for high-resolution CE-MRA of the distal runoff vessels [J].
Du, J ;
Carroll, TJ ;
Wagner, HJ ;
Vigen, K ;
Fain, SB ;
Block, WF ;
Korosec, FR ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (03) :516-522
[9]  
DU J, 2007, P 15 ANN M ISMRM BER
[10]   Simple correction method for k-space trajectory deviations in MRI [J].
Duyn, JH ;
Yang, YH ;
Frank, JA ;
van der Veen, JW .
JOURNAL OF MAGNETIC RESONANCE, 1998, 132 (01) :150-153