Time-resolved, undersampled projection reconstruction imaging for high-resolution CE-MRA of the distal runoff vessels

被引:61
作者
Du, J
Carroll, TJ
Wagner, HJ
Vigen, K
Fain, SB
Block, WF
Korosec, FR
Grist, TM
Mistretta, CA
机构
[1] Univ Wisconsin, Dept Radiol, Clin Sci Ctr E3311, Madison, WI 53792 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53792 USA
[3] Univ Wisconsin, Dept Biomed Engn, Madison, WI 53792 USA
关键词
contrast-enhanced; MR angiography; time-resolved; peripheral;
D O I
10.1002/mrm.10243
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Imaging of the blood vessels below the knee using contrast-enhanced (CE) MRI is challenging due to the need to coordinate image acquisition and arrival of the contrast in the targeted vessels. Time-resolved acquisitions have been successful in consistently capturing images of the arterial phase of the bolus of contrast agent in the distal extremities. Although time-resolved exams are robust in this respect, higher spatial resolution for the depiction of tight stenoses and the small vessels in the lower leg is desirable. A modification to a high-spatial-resolution T-1-weighted pulse sequence (projection reconstruction-time resolved imaging of contrast kinetics (PR-TRICKS)) that improves the through-plane spatial resolution by a factor of 2 and maintains a high frame rate is presented. The under-sampled PR-TRICKS pulse sequence has been modified to double the spatial resolution in the slice direction by acquiring high-spatial-frequency slice data only after first pass of the bolus of contrast agent. The acquisition reported in the present work (PR-hyperTRICKS) has been used to image healthy volunteers and patients with known vascular disease. The temporal resolution was found to be beneficial in capturing arterial phase images in the presence of asymmetric filling of vessels. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:516 / 522
页数:7
相关论文
共 34 条
[1]  
BLOCK WF, 2000, ISMRM WORKSH MIN MR, P54
[2]   Carotid bifurcation: Evaluation of time-resolved three-dimensional contrast-enhanced MR angiography [J].
Carroll, TJ ;
Korosec, FR ;
Petermann, GM ;
Grist, TM ;
Turski, PA .
RADIOLOGY, 2001, 220 (02) :525-532
[3]  
CARROLL TJ, 2001, P 13 INT WORKSH MRA, P42
[4]   Gadolinium-enhanced three-dimensional MR angiography of the entire aorta and iliac arteries with dynamic manual table translation [J].
Earls, JP ;
DeSena, S ;
Bluemke, DA .
RADIOLOGY, 1998, 209 (03) :844-849
[5]   Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector [J].
Earls, JP ;
Rofsky, NM ;
DeCorato, DR ;
Krinsky, GA ;
Weinreb, JC .
RADIOLOGY, 1996, 201 (03) :705-710
[6]   Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography [J].
Foo, TKF ;
Saranathan, M ;
Prince, MR ;
Chenevert, TL .
RADIOLOGY, 1997, 203 (01) :275-280
[7]   High-spatial-resolution multistation MR imaging of lower-extremity peripheral vasculature with segmented volume acquisition: Feasibility study [J].
Foo, TKF ;
Ho, VB ;
Hood, MN ;
Marcos, HB ;
Hess, SL ;
Choyke, PL .
RADIOLOGY, 2001, 219 (03) :835-841
[8]  
Goldfarb JW, 2000, J MAGN RESON IMAGING, V11, P201, DOI 10.1002/(SICI)1522-2586(200002)11:2<201::AID-JMRI19>3.0.CO
[9]  
2-4
[10]   Dynamic 3D MR angiography of the pulmonary arteries in under four seconds [J].
Goyen, M ;
Laub, G ;
Ladd, ME ;
Debatin, JF ;
Barkhausen, J ;
Truemmler, KH ;
Bosk, S ;
Ruehm, SG .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (03) :372-377