Dynamic 3D MR angiography of the pulmonary arteries in under four seconds

被引:79
作者
Goyen, M [1 ]
Laub, G [1 ]
Ladd, ME [1 ]
Debatin, JF [1 ]
Barkhausen, J [1 ]
Truemmler, KH [1 ]
Bosk, S [1 ]
Ruehm, SG [1 ]
机构
[1] Univ Hosp Essen, Dept Diagnost Radiol, D-45122 Essen, Germany
关键词
MR angiography; pulmonary arteries; pulmonary embolism; ultrafast imaging; dynamic MRA;
D O I
10.1002/jmri.1053
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Although 3D MRA has been shown to provide excellent depiction of the pulmonary arterial tree, Its clinical use has been limited due to lengthy breath-holding requirements. Employing the newest gradient generation (1.5 T MR system, amplitude of 40 mT/m and a slew rate of 200 mT/m/msec), we evaluated a technique permitting the dynamic acquisition of 3D data sets of the entire pulmonary tree in under 4 seconds. Coronal image sets were collected using a repetition time of 1.64 msec and an echo time of 0.6 msec, resulting in an acquisition time of 3.74 seconds. Three volunteers and eight dyspneic patients with known or suspected pulmonary embolism underwent NM of the pulmonary arteries. The pulmonary arterial tree was visible to a subsegmental level in all examined subjects. Regarding the presence of pulmonary emboli in four patients, there was complete concordance between MR angiographic findings and those of corroborative studies. We conclude that diagnostic AII;MRA of the pulmonary vasculature can be obtained even in patients with severe respiratory distress. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:372 / 377
页数:6
相关论文
共 19 条
[1]   Noninvasive assessment of regional ventilation in the human lung using oxygen-enhanced magnetic resonance imaging [J].
Edelman, RR ;
Hatabu, H ;
Tadamura, E ;
Li, W ;
Prasad, PV .
NATURE MEDICINE, 1996, 2 (11) :1236-1239
[2]   DETECTION OF DEEP VENOUS THROMBOSIS - PROSPECTIVE COMPARISON OF MR-IMAGING WITH CONTRAST VENOGRAPHY [J].
EVANS, AJ ;
SOSTMAN, HD ;
KNELSON, MH ;
SPRITZER, CE ;
NEWMAN, GE ;
PAINE, SS ;
BEAM, CA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (01) :131-139
[3]   PULMONARY ANGIOGRAPHY WITH MR-IMAGING - PRELIMINARY CLINICAL-EXPERIENCE [J].
GRIST, TM ;
SOSTMAN, HD ;
MACFALL, JR ;
FOO, TK ;
SPRITZER, CE ;
WITTY, L ;
NEWMAN, GE ;
DEBATIN, JF ;
TAPSON, V ;
SALTZMAN, HA .
RADIOLOGY, 1993, 189 (02) :523-530
[4]   Time-resolved contrast-enhanced 3D MR angiography [J].
Korosec, FR ;
Frayne, R ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) :345-351
[5]  
Korosec FR, 1999, JMRI-J MAGN RESON IM, V10, P317, DOI 10.1002/(SICI)1522-2586(199909)10:3<317::AID-JMRI14>3.0.CO
[6]  
2-M
[7]  
MEANEY JF, 1997, NEW ENGL J MED, V20, P1422
[8]   Stepping-table gadolinium-enhanced digital subtraction MR angiography of the aorta and lower extremity arteries: Preliminary experience [J].
Meaney, JFM ;
Ridgway, JP ;
Chakraverty, S ;
Robertson, I ;
Kessel, D ;
Radjenovic, A ;
Kouwenhoven, M ;
Kassner, A ;
Smith, MA .
RADIOLOGY, 1999, 211 (01) :59-67
[9]  
Meaney JFM, 1999, JMRI-J MAGN RESON IM, V10, P326, DOI 10.1002/(SICI)1522-2586(199909)10:3<326::AID-JMRI15>3.3.CO
[10]  
2-C