Carotid bifurcation: Evaluation of time-resolved three-dimensional contrast-enhanced MR angiography

被引:36
作者
Carroll, TJ
Korosec, FR
Petermann, GM
Grist, TM
Turski, PA
机构
[1] Univ Wisconsin, Clin Sci Ctr E3 311, Dept Phys Med, Madison, WI 53792 USA
[2] Univ Wisconsin, Clin Sci Ctr E3 311, Dept Radiol, Madison, WI 53792 USA
[3] Tripler Army Med Ctr, Dept Radiol, Honolulu, HI 96859 USA
关键词
carotid arteries; MR; magnetic resonance (MR); technology;
D O I
10.1148/radiology.220.2.r01au43525
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A magnetic resonance (MR) angiographic protocol was evaluated in the carotid bifurcation with use of a pulse sequence for time-resolved three-dimensional imaging of contrast material kinetics. The enhancement ratio, a quantitative measure of contrast enhancement, indicated that all studies included an image obtained near the peak of the intraarterial concentration of contrast agent (enhancement ratio, 90% +/- 9 [standard deviation]). Studies acquired at a higher frame rate (4.1-4.9 seconds) exhibited less venous enhancement (enhancement ratio, 25% +/- 16) than studies acquired with slower (6.0-9.6-second) frame rates (enhancement ratio, 46% +/- 25).
引用
收藏
页码:525 / 532
页数:8
相关论文
共 28 条
  • [1] Carroll TJ, 2000, MAGN RESON MED, V44, P817, DOI 10.1002/1522-2594(200011)44:5<817::AID-MRM22>3.0.CO
  • [2] 2-X
  • [3] Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector
    Earls, JP
    Rofsky, NM
    DeCorato, DR
    Krinsky, GA
    Weinreb, JC
    [J]. RADIOLOGY, 1996, 201 (03) : 705 - 710
  • [4] HALVING MR IMAGING TIME BY CONJUGATION - DEMONSTRATION AT 3.5 KG
    FEINBERG, DA
    HALE, JD
    WATTS, JC
    KAUFMAN, L
    MARK, A
    [J]. RADIOLOGY, 1986, 161 (02) : 527 - 531
  • [5] Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography
    Foo, TKF
    Saranathan, M
    Prince, MR
    Chenevert, TL
    [J]. RADIOLOGY, 1997, 203 (01) : 275 - 280
  • [6] Goldfarb JW, 2000, J MAGN RESON IMAGING, V11, P201, DOI 10.1002/(SICI)1522-2586(200002)11:2<201::AID-JMRI19>3.0.CO
  • [7] 2-4
  • [8] A FAST, ITERATIVE, PARTIAL-FOURIER TECHNIQUE CAPABLE OF LOCAL PHASE RECOVERY
    HAACKE, EM
    LINDSKOG, ED
    LIN, W
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1991, 92 (01): : 126 - 145
  • [9] Test bolus examination in the carotid artery at dynamic gadolinium-enhanced MR angiography
    Kim, JK
    Farb, RI
    Wright, GA
    [J]. RADIOLOGY, 1998, 206 (01) : 283 - 289
  • [10] Time-resolved contrast-enhanced 3D MR angiography
    Korosec, FR
    Frayne, R
    Grist, TM
    Mistretta, CA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) : 345 - 351