Separation of Heart Sound Signal from Noise in Joint Cycle Frequency-Time-Frequency Domains Based on Fuzzy Detection

被引:48
作者
Tang, Hong [1 ]
Li, Ting [2 ]
Park, Yongwan [3 ]
Qiu, Tianshuang
机构
[1] Dalian Univ Technol, Dept Biomed Engn, Fac Elect Informat & Elect Engn, Dalian 116024, Liaoning, Peoples R China
[2] Dalian Nationalities Univ, Coll Electromech & Informat Engn, Dalian 116600, Peoples R China
[3] Yeungnam Univ, Dept Informat & Commun, Gyeongsangbuk Do 712749, South Korea
基金
中国国家自然科学基金;
关键词
Fuzzy detection; heart sound signal; joint cycle frequency-time-frequency domains; noise reduction; PULMONARY COMPONENTS;
D O I
10.1109/TBME.2010.2051225
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Noise is generally unavoidable during recordings of heart sound signal. Therefore, noise reduction is one of the important preprocesses in the analysis of heart sound signal. This was achieved in joint cycle frequency-time-frequency domains in this study. Heart sound signal was decomposed into components (called atoms) characterized by time delay, frequency, amplitude, time width, and phase. It was discovered that atoms of heart sound signal congregate in the joint domains. On the other hand, atoms of noise were dispersed. The atoms of heart sound signal could, therefore, be separated from the atoms of noise based on fuzzy detection. In a practical experiment, heart sound signal was successfully separated from lung sounds and disturbances due to chest motion. Computer simulations for various clinical heart sound signals were also used to evaluate the performance of the proposed noise reduction. It was shown that heart sound signal can be reconstructed from simulated complex noise (perhaps non-Gaussian, nonstationary, and colored). The proposed noise reduction can recover variations in the both waveform and time delay of heart sound signal during the reconstruction. Correlation coefficient and normalized residue were used to indicate the closeness of the reconstructed and noise-free heart sound signal. Correlation coefficient may exceed 0.90 and normalized residue may be around 0.10 in 0-dB noise environment, even if the phonocardiogram signal covers only ten cardiac cycles.
引用
收藏
页码:2438 / 2447
页数:10
相关论文
共 12 条
[1]   The embedded digital stethoscope uses the adaptive noise cancellation filter and the Type I Chebyshev IIR bandpass filter to reduce the noise of the heart sound [J].
Bai, YW ;
Lu, CL .
HEALTHCOM 2005: 7TH INTERNATIONAL WORKSHOP ON ENTERPRISE NETWORKING AND COMPUTING IN HEALTHCARE INDUSTRY, PROCEEDINGS, 2005, :278-281
[2]   Heart instantaneous frequency (HIF): An alternative approach to extract heart rate variability [J].
Barros, AK ;
Ohnishi, N .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (08) :850-855
[3]   DISTRIBUTION OF AORTIC MECHANICAL PROSTHETIC VALVE CLOSURE SOUND MODEL PARAMETERS ON THE SURFACE OF THE CHEST [J].
BAYKAL, A ;
IDER, YZ ;
KOYMEN, H .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (04) :358-370
[4]   HEART-SOUND PROCESSING BY AVERAGE AND VARIANCE CALCULATION - PHYSIOLOGIC BASIC AND CLINICAL IMPLICATIONS [J].
BEYAR, R ;
LEVKOVITZ, S ;
BRAUN, S ;
PALTI, Y .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (09) :591-596
[5]   Computerized heart sounds analysis [J].
Debbal, S. M. ;
Bereksi-Reguig, F. .
COMPUTERS IN BIOLOGY AND MEDICINE, 2008, 38 (02) :263-280
[6]   A STUDY OF PROSTHETIC HEART-VALVE SOUNDS [J].
KOYMEN, H ;
ALTAY, BK ;
IDER, YZ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (11) :853-863
[7]   Analysis of the second heart sound for diagnosis of paediatric heart disease [J].
Leung, TS ;
White, PR ;
Cook, J ;
Collis, WB ;
Brown, E ;
Salmon, AP .
IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 1998, 145 (06) :285-290
[8]  
PAUL AS, 2006, P 28 IEEE EMBS ANN I, P3385
[9]   Modified forward-backward overdetermined Prony's method and its application in modelling heart sounds [J].
Sava, HP ;
McDonnell, JTE .
IEE PROCEEDINGS-VISION IMAGE AND SIGNAL PROCESSING, 1995, 142 (06) :375-380
[10]   Noise and Disturbance Reduction for Heart Sounds in Cycle-Frequency Domain Based on Nonlinear Time Scaling [J].
Tang, Hong ;
Li, Ting ;
Qiu, Tianshuang .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (02) :325-333