S-SWAT (softer single-wavelength anomalous technique): potential in high-throughput protein crystallography

被引:34
作者
Olczak, A
Cianci, M
Hao, Q
Rizkallah, PJ
Raftery, J
Helliwell, JR
机构
[1] Univ Manchester, Dept Chem, Manchester M13 9PL, Lancs, England
[2] Tech Univ Lodz, Inst Gen & Ecol Chem, PL-90924 Lodz, Poland
[3] CCLRC, Daresbury Lab, Warrington WA4 4AD, Cheshire, England
[4] Cornell Univ, Wilson Synchrotron Lab 273, MacCHESS, Ithaca, NY 14853 USA
来源
ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES | 2003年 / 59卷
关键词
D O I
10.1107/S0108767303009693
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The drive for yet higher output of protein crystal structures sustains an interest in streamlining data-collection protocols. Highly organized automated robotics attend to one aspect. The data-collection elapsed time also depends on the number of wavelengths used, the data redundancy and the desired diffraction resolution limit. Synchrotron-radiation beamlines offer a centralized data-collection approach with considerable flexibility of choice of wavelength(s) with high beam intensity and fine collimation. The arrival of automated IPs (imaging plates) and CCDs (charge-coupled devices) with sample freezing has widened the scope for ease of data collection and achieving a high redundancy, the latter at the cost of elapsed time per sample. This paper reports a single-wavelength approach where a large optimized f" signal involving the Xe L1-absorption edge is harnessed. Even with modest data redundancy (7), a high-quality electron-density map was obtained from that single data set when combined with phase improvement methods. Two phasing protocols are compared for the same data set. Resolution extension (to 1.4 Angstrom), in this test, was also done but via a second data set. In future, with a tilted detector geometry, full diffraction resolution will be collectable in one experiment on the one beamline. Moreover, careful minimization of beamline Be window thickness on the new Daresbury SRS Multipole Wiggler Beamline 10 will maximize the 2-3 Angstrom (softer) wavelength intensity performance specification. The work has application to the harnessing of iodine f" optimized signals and enhanced sulfur f", as well as xenon f", in protein crystallography. This approach, softer-SWAT, should 'swat' many protein structures when it comes online.
引用
收藏
页码:327 / 334
页数:8
相关论文
共 49 条
[1]   THE CCP4 SUITE - PROGRAMS FOR PROTEIN CRYSTALLOGRAPHY [J].
BAILEY, S .
ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 1994, 50 :760-763
[2]   Sulfur distribution in bacteriorhodopsin from multiple wavelength anomalous diffraction near the sulfur K-edge with synchrotron x-ray radiation [J].
Behrens, W ;
Otto, H ;
Stuhrmann, HB ;
Heyn, MP .
BIOPHYSICAL JOURNAL, 1998, 75 (01) :255-263
[3]  
Carpentier P, 2000, CELL MOL BIOL, V46, P915
[4]   Apocrustacyanin A1 from the lobster carotenoprotein α-crustacyanin:: crystallization and initial X-ray analysis involving softer X-rays [J].
Chayen, NE ;
Cianci, M ;
Olczak, A ;
Raftery, J ;
Rizkallah, PJ ;
Zagalsky, PF ;
Helliwell, JR .
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2000, 56 :1064-1066
[5]   Structure of lobster apocrustacyanin A1 using softer X-rays [J].
Cianci, M ;
Rizkallah, PJ ;
Olczak, A ;
Raftery, J ;
Chayen, NE ;
Zagalsky, PF ;
Helliwell, JR .
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2001, 57 :1219-1229
[6]   THE THEORY OF THE METHOD OF ISOMORPHOUS REPLACEMENT FOR PROTEIN CRYSTALS .1. [J].
CRICK, FHC ;
MAGDOFF, BS .
ACTA CRYSTALLOGRAPHICA, 1956, 9 (10) :901-908
[7]   Jolly SAD [J].
Dauter, Z ;
Dauter, M ;
Dodson, E .
ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 2002, 58 :494-506
[8]   A cell for producing xenon-derivative crystals for cryocrystallographic analysis [J].
Djinovic-Carugo, K ;
Everitt, P ;
Tucker, PA .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1998, 31 (31) :812-814
[9]   COMBINING DIRECT METHODS WITH ISOMORPHOUS REPLACEMENT OR ANOMALOUS SCATTERING DATA .7. ABINITIO PHASING OF ONE-WAVELENGTH ANOMALOUS SCATTERING DATA FROM A SMALL PROTEIN [J].
FAN, HF ;
HAO, Q ;
GU, YX ;
QIAN, JZ ;
ZHENG, CD ;
KE, HM .
ACTA CRYSTALLOGRAPHICA SECTION A, 1990, 46 :935-939
[10]   Better structures from better data through better methods:: a review of developments in de novo macromolecular phasing techniques and associated instrumentation at LURE [J].
Fourme, R ;
Shepard, W ;
Schiltz, M ;
Prangé, T ;
Ramin, M ;
Kahn, R ;
de la Fortelle, E ;
Bricogne, G .
JOURNAL OF SYNCHROTRON RADIATION, 1999, 6 :834-844