Improved solvent collection system for a dispersive liquid-liquid microextraction of organochlorine pesticides from water using low-density organic solvent

被引:29
作者
Chang, Chu-Chi [1 ]
Wei, Shuo-Yang [1 ]
Huang, Shang-Da [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Chem, Hsinchu 30013, Taiwan
关键词
Dispersive liquid-liquid microextraction; Gas chromatography; Organochlorine pesticides; Water sample analysis; ATOMIC-ABSORPTION-SPECTROMETRY; PHASE MICROEXTRACTION; GAS-CHROMATOGRAPHY; ORGANOPHOSPHORUS PESTICIDES; MASS-SPECTROMETRY; SINGLE-DROP; SAMPLES; CADMIUM;
D O I
10.1002/jssc.201000728
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
In this study, the organochlorine pesticides (OCPs) levels in lake and tap water samples were determined by a dispersive liquid-liquid microextraction method using a low-density organic solvent and an improved solvent collection system (DLLME-ISCS). This method used a very small volume of a solvent of low toxicity (11 mu L of 1-nonanol and 400 mu L of methanol) to extract OCPs from 10 mL water samples prior to the analysis by GC. After centrifugation in the dispersive liquid-liquid microextraction, there was a liquid organic drop floating between the water surface and the glass wall of the centrifuge tube. The liquid organic drop (with some water phase) was transferred into a microtube (3mm x 15 mm) with a syringe. The organic and aqueous phases were separated in the microtube immediately. Then, 1 mu L of the organic solvent (which was in the upper portion of liquid in the microtube) was easily collected by a syringe and injected into the GC-ECD system for the analysis. Under optimum conditions, the linear range of this method was 5-5000 ng/L for most of the analytes. The correlation coefficient was higher than 0.997. Enrichment factors ranged from 1309 to 3629. The relative recoveries ranged from 73 to 119% for lake water samples. The LODs of the method ranged from 0.7 to 9.4 ng/L. The precision of the method ranged from 1.0 to 10.8% for lake water.
引用
收藏
页码:837 / 843
页数:7
相关论文
共 32 条
[1]
Development of a sequential injection dispersive liquid-liquid microextraction system for electrothermal atomic absorption spectrometry by using a hydrophobic sorbent material: Determination of lead and cadmium in natural waters [J].
Anthemidis, Aristidis N. ;
Ioannou, Kallirroy-Ioanna G. .
ANALYTICA CHIMICA ACTA, 2010, 668 (01) :35-40
[2]
SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[3]
Dispersive liquid-liquid microextraction combined with gas chromatography-flame photometric detection - Very simple, rapid and sensitive method for the determination of organophosphorus pesticides in water [J].
Berijani, Sana ;
Assadi, Yaghoub ;
Anbia, Mansoor ;
Milani Hosseini, Mohammad-Reza ;
Aghaee, Elham .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1123 (01) :1-9
[4]
Determination of alkylphenols in eluates from pyrolysis solid residues using dispersive liquid-liquid microextraction [J].
Bernardo, M. ;
Goncalves, M. ;
Lapa, N. ;
Mendes, B. .
CHEMOSPHERE, 2010, 79 (11) :1026-1032
[5]
Determination of organochlorine pesticides in water samples by dispersive liquid-liquid microextraction coupled to gas chromatography-mass spectrometry [J].
Cortada, Carol ;
Vidal, Lorena ;
Pastor, Raul ;
Santiago, Noemi ;
Canals, Antonio .
ANALYTICA CHIMICA ACTA, 2009, 649 (02) :218-221
[6]
Determination of organochlorine pesticides in complex matrices by single-drop microextraction coupled to gas chromatography-mass spectrometry [J].
Cortada, Carol ;
Vidal, Lorena ;
Tejada, Sergio ;
Romo, Alicia ;
Canals, Antonio .
ANALYTICA CHIMICA ACTA, 2009, 638 (01) :29-35
[7]
DAVIS DL, 1995, SCI AM, V273, P166
[8]
EPA, 2009, EPA 816-F-09-004
[9]
Use of a capillary tube for collecting an extraction solvent lighter than water after dispersive liquid-liquid microextraction and its application in the determination of parabens in different samples by gas chromatography-Flame ionization detection [J].
Farajzadeh, M. A. ;
Djozan, Dj. ;
Bakhtiyari, R. Fazeli .
TALANTA, 2010, 81 (4-5) :1360-1367
[10]
Liquid chromatographic determination of benomyl in water samples after dispersive liquid-liquid microextraction [J].
Farhadi, Khalil ;
Farajzadeh, Mir Ali ;
Matin, Amir Abbas .
JOURNAL OF SEPARATION SCIENCE, 2009, 32 (14) :2442-2447