Use of a capillary tube for collecting an extraction solvent lighter than water after dispersive liquid-liquid microextraction and its application in the determination of parabens in different samples by gas chromatography-Flame ionization detection
被引:151
作者:
Farajzadeh, M. A.
[1
]
Djozan, Dj.
[1
]
Bakhtiyari, R. Fazeli
[1
]
机构:
[1] Univ Tabriz, Dept Analyt Chem, Fac Chem, Tabriz, Iran
来源:
关键词:
Dispersive liquid-liquid microextraction;
Sample preparation;
Preservatives;
Parabens;
Gas chromatography;
SUPERCRITICAL-FLUID EXTRACTION;
SOLID-PHASE EXTRACTION;
MASS-SPECTROMETRY;
ZONE-ELECTROPHORESIS;
COSMETIC PRODUCTS;
ORGANIC-COMPOUNDS;
BENZOIC-ACID;
SORBIC ACID;
GC-MS;
PRESERVATIVES;
D O I:
10.1016/j.talanta.2010.02.035
中图分类号:
O65 [分析化学];
学科分类号:
070302 [分析化学];
摘要:
In this study a new dispersive liquid-liquid microextraction (DLLME) method is presented on the basis of a safe organic solvent, octanol, which is lighter than water The proposed method is used for the extraction and pre-concentration of sonic preservatives including methyl paraben (Mep), ethyl paraben (Etp) and propyl paraben (Prp) from different matrices. The extracted compounds are monitored by gas chromatography-flame ionization detector (GC-FID) A mixture of suitable extraction and dispersive solvents including 20 mu L octanol and 05 mL acetone is quickly injected into the aqueous sample The mixture is centrifuged for 10 min at 6000 rpm, so a small drop of extraction solvent collects on the water surface A portion of the collected solvent is removed by a capillary tube through simple dipping the tube into organic solvent drop 0.4 mu L. of extract into the tube is removed by a microsyringe and injected into GC. Some effective parameters such as kinds and volumes of extraction and dispersive solvents as well as extraction time have to be investigated Under optimum conditions, enrichment factors and recoveries of the studied compounds were obtained in the range of 100-276 and 25-72%, respectively Linear ranges of the calibration curves were between 005 and 30 for methyl- and 0.02 and 30 mu g mL(-1) for ethyl- and propyl parabens, respectively Limit of detection for methyl paraben was 0 015 mu g mL(-1) and those of ethyl- and propyl parabens were 0.005 mu g mL(-1). Relative standard deviations (RSDs %) for six repeated measurements (C = 2 mu g mL(-1)) were 2% for methyl-, and ethyl parabens and 3% for propyl parabens, respectively (C) 2010 Elsevier B V All rights reserved.
引用
收藏
页码:1360 / 1367
页数:8