Continuum damage model for bioresorbable magnesium alloy devices - Application to coronary stents

被引:128
作者
Gastaldi, D. [1 ]
Sassi, V. [1 ]
Petrini, L. [1 ]
Vedani, M. [2 ]
Trasatti, S. [3 ]
Migliavacca, F. [1 ]
机构
[1] Politecn Milan, Dept Struct Engn, Lab Biol Struct Mech, I-20133 Milan, Italy
[2] Politecn Milan, Dept Mech, I-20133 Milan, Italy
[3] Univ Milan, Dept Phys Chem & Electrochem, I-20122 Milan, Italy
关键词
Bioresorbable stent; Degradable metals; Continuum damage model; Magnesium alloys; Corrosion; Biomaterials; FEM; STRESS-CORROSION CRACKING; AUSTENITIC STAINLESS-STEEL; SIROLIMUS-ELUTING STENTS; IN-VIVO CORROSION; BIODEGRADABLE STENTS; BALLOON ANGIOPLASTY; SODIUM-CHLORIDE; ARTERY DISEASE; METAL STENTS; BARE-METAL;
D O I
10.1016/j.jmbbm.2010.11.003
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
The main drawback of a conventional stenting procedure is the high risk of restenosis. The idea of a stent that "disappears" after having fulfilled its mission is very intriguing and fascinating, since it can be expected that the stent mass decreases in time to allow the gradual transmission of the mechanical load to the surrounding tissues owing to controlled dissolution by corrosion. Magnesium and its alloys are appealing materials for designing biodegradable stents. The objective of this work is to develop, in a finite element framework, a model of magnesium degradation that is able to predict the corrosion rate, thus providing a valuable tool for the design of bioresorbable stents. Continuum damage mechanics is suitable for modeling several damage mechanisms, including different types of corrosion. In this study, the damage is assumed to be the superposition of stress corrosion and uniform microgalvanic corrosion processes. The former describes the stress-mediated localization of the corrosion attack through a stress-dependent evolution law, while the latter affects the free surface of the material exposed to an aggressive environment. Comparisons with experimental tests show that the developed model can reproduce the behavior of different magnesium alloys subjected to static corrosion tests. The study shows that parameter identification for a correct calibration of the model response on the results of uniform and stress corrosion experimental tests is reachable. Moreover, three-dimensional stenting procedures accounting for interaction with the arterial vessel are simulated, and it is shown how the proposed modeling approach gives the possibility of accounting for the combined effects of an aggressive environment and mechanical loading. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:352 / 365
页数:14
相关论文
共 62 条
[1]
NONLOCAL CONTINUUM DAMAGE, LOCALIZATION INSTABILITY AND CONVERGENCE [J].
BAZANT, ZP ;
PIJAUDIERCABOT, G .
JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 1988, 55 (02) :287-293
[2]
BELYTSCHKO T, 1994, J NUMER METHODS ENG, V36, P4245
[3]
Corrosion fatigue behavior of extruded magnesium alloy AZ61 under three different corrosive environments [J].
Bhuiyan, Md. Shahnewaz ;
Mutoh, Yoshiharu ;
Murai, Tsutomu ;
Iwakami, Shinpei .
INTERNATIONAL JOURNAL OF FATIGUE, 2008, 30 (10-11) :1756-1765
[4]
Mechanical aspects of corrosion fatigue and stress corrosion cracking [J].
Bolotin, VV ;
Shipkov, AA .
INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2001, 38 (40-41) :7297-7318
[5]
AMS INSIGHT-Absorbable Metal Stent Implantation for Treatment of Below-the-Knee Critical Limb Ischemia: 6-Month Analysis [J].
Bosiers, Marc .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 32 (03) :424-435
[6]
Assessment of tissue prolapse after balloon-expandable stenting: Influence of stent cell geometry [J].
Capelli, Claudio ;
Gervaso, Francesca ;
Petrini, Lorenza ;
Dubini, Gabriele ;
Migliavacca, Francesco .
MEDICAL ENGINEERING & PHYSICS, 2009, 31 (04) :441-447
[7]
Colombo A, 2000, CIRCULATION, V102, P371
[8]
A simple model for slow strain rate and constant load corrosion tests of austenitic stainless steel in acid aqueous solution containing sodium chloride [J].
da Costa-Mattos, H. S. ;
Bastos, I. N. ;
Gomes, J. A. C. P. .
CORROSION SCIENCE, 2008, 50 (10) :2858-2866
[9]
Realistic finite element-based stent design: The impact of balloon folding [J].
De Beule, Matthieu ;
Mortier, Peter ;
Carlier, Stphane G. ;
Verhegghe, Benedict ;
Van Impe, Rudy ;
Verdonck, Pascal .
JOURNAL OF BIOMECHANICS, 2008, 41 (02) :383-389
[10]
De Borst R., 1993, Engineering Computations, V10, P99, DOI 10.1108/eb023897