Classifying Human Motion Quality for Knee Osteoarthritis Using Accelerometers

被引:46
作者
Taylor, Portia E. [1 ]
Almeida, Gustavo J. M. [2 ]
Kanade, Takeo [3 ]
Hodgins, Jessica K. [3 ]
机构
[1] Carnegie Mellon Univ, Dept Biomed Engn, Pittsburgh, PA 15213 USA
[2] Univ Pittsburgh, Dept Phys Therapy, Pittsburgh, PA 15213 USA
[3] Univ Pittsburgh, Robert Inst Carnegie Mellon, Pittsburgh, PA 15213 USA
来源
2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) | 2010年
关键词
D O I
10.1109/IEMBS.2010.5627665
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
In this paper, we describe methods for assessment of exercise quality using body-worn tri-axial accelerometers. We assess exercise quality by building a classifier that labels incorrect exercises. The incorrect performances are divided into a number of classes of errors as defined by a physical therapist. We focus on exercises commonly prescribed for knee osteoarthritis: standing hamstring curl, reverse hip abduction, and lying straight leg raise. The methods presented here will form the basis for an at-home rehabilitation device that will recognize errors in patient exercise performance, provide appropriate feedback on the performance, and motivate the patient to continue the prescribed regimen.
引用
收藏
页码:339 / 343
页数:5
相关论文
共 15 条
[1]
[Anonymous], BRIT MED J
[2]
[Anonymous], 2005, J NEUROENGINEERING R
[3]
[Anonymous], OSTEOARTHRITIS DEGEN
[4]
[Anonymous], 2009, WEKA DATA MINING SOF
[5]
[Anonymous], MACH LEARN P 13 INT
[6]
Activity recognition from user-annotated acceleration data [J].
Bao, L ;
Intille, SS .
PERVASIVE COMPUTING, PROCEEDINGS, 2004, 3001 :1-17
[7]
Brutovsky J., 2006, IEEE ENG MED BIOL
[8]
Implementation of a real-time human movement classifier using a triaxial accelerometer for ambulatory monitoring [J].
Karantonis, DM ;
Narayanan, MR ;
Mathie, M ;
Lovell, NH ;
Celler, BG .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2006, 10 (01) :156-167
[9]
Analysis of low resolution accelerometer data for continuous human activty recognition [J].
Krishnan, Narayanan C. ;
Panchanathan, Sethuraman .
2008 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING, VOLS 1-12, 2008, :3337-3340
[10]
A study on the activity classification using a triaxial accelerometer [J].
Lee, SH ;
Park, HD ;
Hong, SY ;
Lee, KJ ;
Kim, YH .