Implementation of a real-time human movement classifier using a triaxial accelerometer for ambulatory monitoring

被引:804
作者
Karantonis, DM [1 ]
Narayanan, MR
Mathie, M
Lovell, NH
Celler, BG
机构
[1] Univ New S Wales, Grad Sch Biomed Engn, Sydney, NSW 2052, Australia
[2] Univ New S Wales, Sch Elect Engn & Telecommun, Sydney, NSW 2052, Australia
来源
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE | 2006年 / 10卷 / 01期
关键词
accelerometer; ambulatory monitoring; home telecare; movement classification;
D O I
10.1109/TITB.2005.856864
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The real-time monitoring of human movement can provide valuable information regarding an individual's degree of functional ability and general level of activity. This paper presents the implementation of a real-time classification system for the types of human movement associated with the data acquired from a single, waist-mounted triaxial accelerometer unit. The major advance proposed by the system is to perform the vast majority of signal processing onboard the wearable unit using embedded intelligence. In this way, the system distinguishes between periods of activity and rest, recognizes the postural orientation of the wearer, detects events such as walking and falls, and provides an estimation of metabolic energy expenditure. A laboratory-based trial involving six subjects was undertaken, with results indicating an overall accuracy of 90.8% across a series of 12 tasks (283 tests) involving a variety of movements related to normal daily activities. Distinction between activity and rest was performed without error; recognition of postural orientation was carried out with 94.1% accuracy, classification of walking was achieved with less certainty (83.3% accuracy), and detection of possible falls was made with 95.6% accuracy. Results demonstrate the feasibility of implementing an accelerometry-based, real-time movement classifier using embedded intelligence.
引用
收藏
页码:156 / 167
页数:12
相关论文
共 21 条
  • [1] AMINIAN K, 1995, MED SCI SPORT EXER, V27, P226
  • [2] Physical activity monitoring based on accelerometry: validation and comparison with video observation
    Aminian, K
    Robert, P
    Buchser, EE
    Rutschmann, B
    Hayoz, D
    Depairon, M
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (03) : 304 - 308
  • [3] THE FREQUENCY CONTENT OF GAIT
    ANTONSSON, EK
    MANN, RW
    [J]. JOURNAL OF BIOMECHANICS, 1985, 18 (01) : 39 - 47
  • [4] BOUTEN CV, 1994, MED SCI SPORT EXER, V26, P1516
  • [5] Daily physical activity assessment: Comparison between movement registration and doubly labeled water
    Bouten, CVC
    VerboeketVandeVenne, WPHG
    Westerterp, KR
    Verduin, M
    Janssen, JD
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (02) : 1019 - 1026
  • [6] A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity
    Bouten, CVC
    Koekkoek, KTM
    Verduin, M
    Kodde, R
    Janssen, JD
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (03) : 136 - 147
  • [7] Assessment of posture and motion by multichannel piezoresistive accelerometer recordings
    Fahrenberg, J
    Foerster, F
    Smeja, M
    Muller, W
    [J]. PSYCHOPHYSIOLOGY, 1997, 34 (05) : 607 - 612
  • [8] Motion pattern and posture: Correctly assessed by calibrated accelerometers
    Foerster, F
    Fahrenberg, J
    [J]. BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS, 2000, 32 (03): : 450 - 457
  • [9] Validity of accelerometry for the assessment of moderate intensity physical activity in the field
    Hendelman, D
    Miller, K
    Bagget, C
    Debold, E
    Freedson, P
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) : S442 - S449
  • [10] Kiani K, 1997, Technol Health Care, V5, P307