Bispectral Index Monitoring during Sedation with Sevoflurane, Midazolam, and Propofol

被引:190
作者
Ibrahim, AE [1 ]
Taraday, JK [1 ]
Kharasch, ED [1 ]
机构
[1] Univ Washington, Dept Anesthesiol, Seattle, WA 98195 USA
关键词
D O I
10.1097/00000542-200111000-00019
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Bispectral Index (BIS) has been used to measure sedation depth. Ideally, to guide anesthetic management, range of BIS scores at different sedation levels should not overlap, and BIS should be independent of drug used. This study assessed ability of BIS to predict sedation depth between sevoflurane, propofol, and midazolam. Quality of recovery was also compared. Methods. Patients undergoing surgery with local or regional anesthesia and sedation were randomized to sevoflurane (n = 23), midazolam (n = 21), or propofol (n = 22). Sedation was titrated to Observers's Assessment of Alertness-Sedation score of 3 (responds slowly to voice). BIS and Observers's Assessment of Alertness-Sedation were measured every 5 min. BIS prediction probability (P.) was compared between drugs. Recovery was assessed by BIS and Digit Symbol Substitution and memory tests. Results: Bispectral Index of responders to voice was significantly different from nonresponders (86 +/- 10 vs. 74 +/- 14, mean +/-: SD; P < 0.001) However, wide variability and overlap in BIS were observed (25th-75th percentile, responders vs. non-responders: 79-96 vs. 65-83). BIS of responders was different for sevoflurane versus propofol and midazolam. BIS was a better predictor of propofol sedation than sevoflurane or midazolam (P-K = 0.87 +/- 0.11, 0.76 +/- 0.01, and 0.69 +/- 0.02, respectively; P < 0.05). At 10 min after the procedure, 76, 48, and 24% of sevoflurane, propofol, midazolam patients, respectively, returned to baseline Digit Symbol Substitution scores (P < 0.05). Excitement-disinhibition occurred in 70, 36, and 5% of sevoflurane, propofol, and midazolam patients, respectively (P < 0.05). Conclusion: Individual BIS scores demonstrate significant variability, making it difficult to predict sedation depth. The relation between BIS and sedation depth may not be independent of anesthetic agent. Quality of recovery was similar between drugs, but excitement occurred frequently with sevoflurane.
引用
收藏
页码:1151 / 1159
页数:9
相关论文
共 48 条
[1]  
[Anonymous], 1944, TEACHERS WORD BOOK 3
[2]   Effects on the bispectral index during medium-high dose fentanyl induction with or without propofol supplement [J].
Barr, G ;
Anderson, RE ;
Öwall, A ;
Jakobsson, JG .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2000, 44 (07) :807-811
[3]   Fentanyl and midazolam anaesthesia for coronary bypass surgery:: a clinical study of bispectral electroencephalogram analysis, drug concentrations and recall [J].
Barr, G ;
Anderson, RE ;
Samuelsson, S ;
Öwall, A ;
Jakobsson, JG .
BRITISH JOURNAL OF ANAESTHESIA, 2000, 84 (06) :749-752
[4]  
CHERNIK DA, 1990, J CLIN PSYCHOPHARM, V10, P244
[5]   MEASURES OF FREE-RECALL OF 900 ENGLISH NOUNS - CORRELATIONS WITH IMAGERY, CONCRETENESS, MEANINGFULNESS, AND FREQUENCY [J].
CHRISTIAN, J ;
BICKLEY, W ;
TARKA, M ;
CLAYTON, K .
MEMORY & COGNITION, 1978, 6 (04) :379-390
[6]   Monitoring depth of anesthesia - With emphasis on the application of the bispectral index and the middle latency auditory evoked response to the prevention of recall [J].
Drummond, JC .
ANESTHESIOLOGY, 2000, 93 (03) :876-882
[7]  
Fanard L, 1988, Anaesthesia, V43 Suppl, P87, DOI 10.1111/j.1365-2044.1988.tb09082.x
[8]   Analysis of the EEG bispectrum, auditory evoked potentials and the EEG power spectrum during repeated transitions from consciousness to unconsciousness [J].
Gajraj, RJ ;
Doi, M ;
Mantzaridis, H ;
Kenny, GNC .
BRITISH JOURNAL OF ANAESTHESIA, 1998, 80 (01) :46-52
[9]   THE INTERACTIONS OF MIDAZOLAM AND FLUMAZENIL ON HUMAN-MEMORY AND COGNITION [J].
GHONEIM, MM ;
BLOCK, RI ;
PING, STS ;
ELZAHABY, HM ;
HINRICHS, JV .
ANESTHESIOLOGY, 1993, 79 (06) :1183-1192
[10]   Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers [J].
Glass, PS ;
Bloom, M ;
Kearse, L ;
Rosow, C ;
Sebel, P ;
Manberg, P .
ANESTHESIOLOGY, 1997, 86 (04) :836-847