Effects on the bispectral index during medium-high dose fentanyl induction with or without propofol supplement

被引:36
作者
Barr, G
Anderson, RE
Öwall, A
Jakobsson, JG [1 ]
机构
[1] Karolinska Hosp, Dept Cardiothorac Anaesthet & Intens Care, S-17176 Stockholm, Sweden
[2] Sabbatsbergs Hosp, Dept Anaesthet, S-11382 Stockholm, Sweden
关键词
bispectral index; opiates; fentanyl; propofol; awareness; coronary artery bypass grafting;
D O I
10.1034/j.1399-6576.2000.440707.x
中图分类号
R614 [麻醉学];
学科分类号
100217 [麻醉学];
摘要
Background: The search for a drug-independent monitor to determine depth of anaesthesia and hypnosis continues. The bispectral analysis (BIS) of the EEG correlates well with the clinical dose-response of hypnotic drugs during induction, but the effect on BIS of an opiate induction, as for coronary bypass surgery, is not known. Methods: Fourteen patients scheduled for elective coronary bypass surgery were studied. BIS was recorded during induction in 7 patients receiving 10 mu g/kg fentanyl without any hypnotic agent and in 7 patients receiving 0.5 mg/kg propofol before the fentanyl dose. Results: The effect of fentanyl was very variable both regarding BIS and clinical response. Five of the 7 patients that received only fentanyl lost their response to verbal command within 8 min. BIS values at loss of response varied between 45 and 94. One patient remained awake with BIS 43. All 7 patients receiving propofol before the fentanyl dose lost their response to verbal command within 5 min. BIS values at the time for loss of response varied between 78 and 98. Conclusion: Loss of response to verbal command when a medium-high dose of fentanyl is used for induction cannot be distinguished from wakefulness with adequate sensitivity by BIS. The current BLS algorithm seems not to accurately reflect the hypnotic effects of fentanyl.
引用
收藏
页码:807 / 811
页数:5
相关论文
共 11 条
[1]
Nitrous oxide does not alter bispectral index:: study with nitrous oxide as sole agent and as an adjunct to i.v. anaesthesia [J].
Barr, G ;
Jakobsson, JG ;
Öwall, A ;
Anderson, RE .
BRITISH JOURNAL OF ANAESTHESIA, 1999, 82 (06) :827-830
[2]
Opiate receptors in the periaqueductal gray mediate analgesic effect of nitrous oxide in rats [J].
Fang, F ;
Guo, TZ ;
Davies, MF ;
Maze, M .
EUROPEAN JOURNAL OF PHARMACOLOGY, 1997, 336 (2-3) :137-141
[3]
Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers [J].
Glass, PS ;
Bloom, M ;
Kearse, L ;
Rosow, C ;
Sebel, P ;
Manberg, P .
ANESTHESIOLOGY, 1997, 86 (04) :836-847
[4]
Iselin-Chaves IA, 1998, ANESTH ANALG, V87, P949
[5]
Electroencephalographic derivatives as a tool for predicting the depth of sedation and anesthesia induced by sevoflurane [J].
Katoh, T ;
Suzuki, A ;
Ikeda, K .
ANESTHESIOLOGY, 1998, 88 (03) :642-650
[6]
Bispectral analysis of the electroencephalogram predicts conscious processing of information during propofol sedation and hypnosis [J].
Kearse, LA ;
Rosow, C ;
Zaslavsky, A ;
Connors, P ;
Dershwitz, M ;
Denman, W .
ANESTHESIOLOGY, 1998, 88 (01) :25-34
[7]
Electroencephalographic bispectral index correlates with intraoperative recall and depth of propofol-induced sedation [J].
Liu, J ;
Singh, H ;
White, PF .
ANESTHESIA AND ANALGESIA, 1997, 84 (01) :185-189
[8]
Mi W. D., 1999, European Journal of Anaesthesiology, V16, P47, DOI 10.1046/j.1365-2346.1999.00421.x
[9]
Bispectral EEG index during nitrous oxide administration [J].
Rampil, IJ ;
Kim, JS ;
Lenhardt, R ;
Negishi, C ;
Sessler, DI .
ANESTHESIOLOGY, 1998, 89 (03) :671-677
[10]
A multicenter study of bispectral electroencephalogram analysis for monitoring anesthetic effect [J].
Sebel, PS ;
Lang, E ;
Rampil, IJ ;
White, PF ;
Cork, R ;
Jopling, M ;
Smith, NT ;
Glass, PSA ;
Manberg, P .
ANESTHESIA AND ANALGESIA, 1997, 84 (04) :891-899