Determination of trace metals in urine with an on-line ultrasound-assisted digestion system combined with a flow-injection preconcentration manifold coupled to flame atomic absorption spectrometry

被引:28
作者
Cespon-Romero, R. M. [1 ]
Yebra-Biurrun, M. C. [1 ]
机构
[1] Univ Santiago de Compostela, Fac Chem, Dept Analyt Chem Nutr & Bromatol, Santiago De Compostela 15782, Spain
关键词
metals; urine; flow injection; flame atomic absorption; spectrometry;
D O I
10.1016/j.aca.2008.01.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow analysis method with on-line sample digestion/minicolumn preconcentration/flame atomic absorption spectrometry is described for the determination of trace metals in urine. First, urine sample was on-line ultrasound-assisted digested exploiting the stopped-flow mode, and then the metals were preconcentrated passing the pre-treated sample through a minicolumn containing a chelating resin. A home-made minicolumn of commercially available imminodiacetic functional group resin, Chelite Che was used to preconcentrate trace metals (Cu, Fe, Mn and Ni) from urine. The proposed procedure allowed the determination of the metals with detection limits of 0.5, 1.1, 0.8 and 0.8 mu g L-1, for Cu, Fe, Mn and Ni, respectively. The precision based on replicate analysis was less than 10.0%, and the enrichment factor obtained was between 21.3 (Mn) and 44.1 (Ni), for sample volumes between 2.5 and 5.0 mL, and an eluent volume of 110 mu L. This procedure was applied for determination of metals in urine of workers exposed to welding fumes and urine of unexposed persons (urine control). (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:184 / 191
页数:8
相关论文
共 24 条
[1]   Evaluation of toxic metals in biological samples (scalp hair, blood and urine) of steel mill workers by electrothermal atomic absorption spectrometry [J].
Afridi, Hassan I. ;
Kazi, Tasneem G. ;
Jamali, Mohammad K. ;
Kazi, Gul H. ;
Arain, Mohammad B. ;
Jalbani, Nusrat ;
Shar, Ghulam Q. ;
Sarfaraz, Raja A. .
TOXICOLOGY AND INDUSTRIAL HEALTH, 2006, 22 (09) :381-393
[2]   Development of an on-line solvent extraction system for electrothermal atomic absorption spectrometry utilizing a new gravitational phase separator. Determination of cadmium in natural waters and urine samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (11) :1400-1403
[3]   Gallium trace on-line preconcentration/separation and determination using a polyurethane foam mini-column and flame atomic absorption spectrometry. Application in aluminum alloys, natural waters and urine [J].
Antheraidis, AN ;
Zachariadis, GA ;
Stratis, JA .
TALANTA, 2003, 60 (05) :929-936
[4]  
Aydemir T, 1996, ANAL LETT, V29, P351, DOI 10.1080/00032719608000403
[5]   A rapid Chelex column method for the determination of metal speciation in natural waters [J].
Bowles, KC ;
Apte, SC ;
Batley, GE ;
Hales, LT ;
Rogers, NJ .
ANALYTICA CHIMICA ACTA, 2006, 558 (1-2) :237-245
[6]   On-line electrochemical preconcentration and flame atomic absorption spectrometric determination of manganese in urine samples [J].
Burguera, M ;
Burguera, JL ;
Rivas, D ;
Rondón, C ;
Carrero, P ;
Alarcón, OM ;
de Peña, YP ;
Brunetto, MR ;
Gallignani, M ;
Márquez, OP ;
Márquez, J .
TALANTA, 2005, 68 (02) :219-225
[7]   Determination of cadmium in leaves by ultrasound-assisted extraction prior to hydride generation, pervaporation and atomic absorption detection [J].
Caballo-Lopez, A. ;
de Castro, M. D. Luque .
TALANTA, 2007, 71 (05) :2074-2079
[8]  
Dadfarnia S, 2006, CAN J ANAL SCI SPECT, V51, P302
[9]   Determination of manganese by flame atomic absorption spectrometry after its adsorption onto naphthalene modified with 1-(2-pyridylazo)-2-naphthol (PAN) [J].
dos Anjos, Aparecida P. ;
Cornejo-Ponce, Lorena ;
Cadore, Solange ;
Baccan, Nivaldo .
TALANTA, 2007, 71 (03) :1252-1256
[10]   Determination of urinary lead, cadmium and nickel in steel production workers [J].
Horng, CJ ;
Tsai, JL ;
Horng, PH ;
Lin, SC ;
Lin, SR ;
Tzeng, CC .
TALANTA, 2002, 56 (06) :1109-1115