Sequential injection extraction based on restricted access material for determination of furosemide in serum

被引:24
作者
Huclová, J
Satínsky, D
Maia, T
Karlícek, R
Solich, P
Araújo, AN
机构
[1] Charles Univ, Fac Pharm Hradec Kralove, Dept Analyt Chem, Hradec Kralove, Czech Republic
[2] Univ Porto, Fac Pharm, Dept Chem Phys, P-4050 Oporto, Portugal
关键词
furosemide; sequential injection analysis; restricted access materials; serum;
D O I
10.1016/j.chroma.2004.11.055
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Restricted access material (RAM) column containing 25 mu m C-18 alkyl-diol support was integrated into the sequential injection analysis (SIA) manifold and the SIA-RAM system was tested for direct determination of furosemide in serum. LiChrospher((R)) ADS column based on restricted access material is proposed to direct injection of biofluids. The integration of RAM material into SIA enabled creation of a comprehensive on-line sample clean-up technique combined with fluorescence quantitation of analyte. Centrifuged and diluted serum sample was aspirated into the system and loaded onto the column using acetonitrile-water (2:98), pH 2.7. The analyte was retained on the column while proteins contained in the sample were removed to the waste without precipitation and clogging the column. Interfering substances complicating the detection were washed out by acetonitrile-water (15:85), pH 2.7 in the next step. The extracted analyte was eluted by means of acetonitrile-water (25:75), pH 2.3 to the fluorescence detector (emission filter 385 nm). The whole procedure comprising sample pre-treatment, analyte detection and column reconditioning took 20 min. The recoveries of furosemide from serum lay between 101.4 and 103.4% for three concentrations of analyte. (c) 2004 Elsevier B.V All rights reserved.
引用
收藏
页码:245 / 251
页数:7
相关论文
共 38 条
[1]   High-performance liquid chromatographic determination of furosemide in plasma and urine and its use in bioavailability studies [J].
Abou-Auda, HS ;
Al-Yamani, MJ ;
Morad, AM ;
Bawazir, SA ;
Khan, SZ ;
Al-Khamis, KI .
JOURNAL OF CHROMATOGRAPHY B, 1998, 710 (1-2) :121-128
[2]   ELECTROCHEMICAL DETERMINATION OF THE LOOP DIURETICS PIRETANIDE AND FUROSEMIDE IN PHARMACEUTICAL FORMULATIONS AND URINE [J].
BARROSO, MB ;
ALONSO, RM ;
JIMENEZ, RM .
ANALYTICA CHIMICA ACTA, 1995, 305 (1-3) :332-339
[3]   Determination of piretanide and furosemide in pharmaceuticals and human urine by high-performance liquid chromatography with amperometric detection [J].
Barroso, MB ;
Jimenez, RM ;
Alonso, RM ;
Ortiz, E .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1996, 675 (02) :303-312
[4]   CHROMATOGRAPHIC MONITORING OF DIURETICS IN URINE SAMPLES USING A SODIUM DODECYL-SULFATE PROPANOL MICELLAR ELUENT [J].
BONETDOMINGO, E ;
TORRESLAPASIO, JR ;
MEDINAHERNANDEZ, MJ ;
GARCIAALVAREZCOQUE, MC .
ANALYTICA CHIMICA ACTA, 1994, 287 (03) :201-210
[5]   Use of a three-factor interpretive optimisation strategy in the development of an isocratic chromatographic procedure for the screening of diuretics in urine samples using micellar mobile phases [J].
Carda-Broch, S ;
Torres-Lapasió, JR ;
Esteve-Romero, JS ;
García-Alvarez-Coque, MC .
JOURNAL OF CHROMATOGRAPHY A, 2000, 893 (02) :321-337
[6]   Chromatographic determination of diuretics in urine samples using hybrid micellar mobile phases with fluorimetric detection [J].
Carda-Broch, S ;
Esteve-Romero, JS ;
García-Alvarez-Coque, MC .
ANALYTICA CHIMICA ACTA, 1998, 375 (1-2) :143-154
[7]   Use of a novel cation-exchange restricted-access material for automated sample clean-up prior to the determination of basic drugs in plasma by liquid chromatography [J].
Chiap, P ;
Rbeida, O ;
Christiaens, B ;
Hubert, P ;
Lubda, D ;
Boos, KS ;
Crommen, J .
JOURNAL OF CHROMATOGRAPHY A, 2002, 975 (01) :145-155
[8]   Development of solid-phase chemiluminescence immunoassays for digoxin comparing flow injection and sequential injection techniques [J].
Dreveny, D ;
Michalowski, J ;
Seidl, R ;
Gübitz, G .
ANALYST, 1998, 123 (11) :2271-2276
[9]   Simultaneous high-performance liquid chromatographic assay of furosemide and propranolol HCL and its application in a pharmacokinetic study [J].
El-Saharty, YS .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (04) :699-709
[10]   FUNDAMENTALS OF SINUSOIDAL FLOW SEQUENTIAL INJECTION SPECTROPHOTOMETRY [J].
GUBELI, T ;
CHRISTIAN, GD ;
RUZICKA, J .
ANALYTICAL CHEMISTRY, 1991, 63 (21) :2407-2413